Product comparison · 2 power distribution units (pdus)

APC Easy PDU Metered Zero U 22 kW vs APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets

Add a product
  • 27specifications compared
  • 20differ
  • 7identical
  • 15known for one product only

Key differences

The APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets has 68 A more maximum current than the APC Easy PDU Metered Zero U 22 kW (100 A vs 32 A). The APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets has 46,920 VA more load capacity than the APC Easy PDU Metered Zero U 22 kW (69000 VA vs 22080 VA). The APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets has 29 mm more width than the APC Easy PDU Metered Zero U 22 kW (85 mm vs 56 mm). PDU types: Metered on the APC Easy PDU Metered Zero U 22 kW, Metered-by-outlet, Switched on the APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets. AC outlets quantity: 24 AC outlet(s) on the APC Easy PDU Metered Zero U 22 kW, 48 AC outlet(s) on the APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets.

  • PDU types
    • Easy PDU Metered Zero U 22 kW:Metered
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets:Metered-by-outlet, Switched
  • AC outlets quantity
    • Easy PDU Metered Zero U 22 kW:24 AC outlet(s)
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets:48 AC outlet(s)
  • Power plug
    • Easy PDU Metered Zero U 22 kW:C13 coupler
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets:IEC 60309
  • Nominal input voltage
    • Easy PDU Metered Zero U 22 kW:400 V
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets:415 3 phases
  • Maximum current
    • Easy PDU Metered Zero U 22 kW:32 A
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets:100 A
  • Output voltage
    • Easy PDU Metered Zero U 22 kW:230 V
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets:415 V AC 3 phases
  • Load capacity
    • Easy PDU Metered Zero U 22 kW:22080 VA
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets:69000 VA
  • Compliance certificates
    • Easy PDU Metered Zero U 22 kW:CE, UKCA
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets:RoHS, REACH

Side by side

Differences highlightedShow differences only (off)
Comparison of EPDU2232M, NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 48 Outlets
42 specifications
Design1 differ
PDU typesDiffersMeteredMetered-by-outlet, Switched
TypeThree-phaseThree-phase
Rack capacity0U0U
MountingVerticalVertical
Product colourBlackBlack
UpgradeableKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces3 differ
AC outlets quantityDiffers24 AC outlet(s)48 AC outlet(s)
Power plugDiffersC13 couplerIEC 60309
AC outlet typesDiffersC13 coupler, C19 couplerC13 coupler, C15 coupler, C19 coupler, C21 coupler
Input connection typeKnown for oneUnknown — not stated by the sourceIEC 309 100 A
Featuresidentical
International Protection (IP) codeKnown for oneUnknown — not stated by the sourceIP67
Power4 differ
Nominal input voltageDiffers400 V415 3 phases
AC input frequency50/60 Hz50/60 Hz
Maximum currentDiffers32 A100 A
Output voltageDiffers230 V415 V AC 3 phases
Load capacityDiffers22080 VA69000 VA
Number of phases33
Nominal output voltageKnown for one230 VUnknown — not stated by the source
Certificates1 differ
Compliance certificatesDiffersCE, UKCARoHS, REACH
Sustainabilityidentical
Doesn't containKnown for oneUnknown — not stated by the sourceSilicone
Operational conditions3 differ
Operating temperature (T-T)Differs-5 - 50 °C-5 - 60 °C
Storage temperature (T-T)Differs-25 - 65 °C-20 - 60 °C
Operating relative humidity (H-H)Differs5 - 95%5 - 90%
Storage relative humidity (H-H)5 - 95%5 - 95%
Non-operating altitudeKnown for oneUnknown — not stated by the source0 - 15240 m
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers56 mm85 mm
DepthDiffers56 mm85 mm
HeightDiffers1650 mm2030 mm
WeightDiffers4.85 kg22.8 kg
Packaging data4 differ
Package weightDiffers6.05 kg28.6 kg
Package widthDiffers170 mm350 mm
Package depthDiffers1810 mm165 mm
Package heightDiffers1260 mm2320 mm
Technical detailsidentical
Packaging recycled materialsKnown for oneUnknown — not stated by the sourceRecycled cardboard
Preferred mounting positionKnown for oneUnknown — not stated by the sourceno preference
Packaging without single use plasticKnown for oneUnknown — not stated by the sourceYes
SCIP numberKnown for oneUnknown — not stated by the source31346aed-552c-4a16-81d9-e683a383b6da
Sustainable packagingKnown for oneUnknown — not stated by the sourceNo
Take-back systemKnown for oneUnknown — not stated by the sourceNo
Logistics dataidentical
Customs product code (TARIC)Known for oneUnknown — not stated by the source8537109899
Total carbon footprint (kg of CO2e)Known for one1655Unknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.