The APC Easy PDU Metered Zero U 22 kW has 14,680 VA more load capacity than the APC NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet (22080 VA vs 7400 VA). The APC Easy PDU Metered Zero U 22 kW has 2 more phases than the APC NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet (3 vs 1). The APC NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet has 19 mm more depth than the APC Easy PDU Metered Zero U 22 kW (75 mm vs 56 mm). AC outlets quantity: 24 AC outlet(s) on the APC Easy PDU Metered Zero U 22 kW, 40 AC outlet(s) on the APC NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet. Nominal input voltage: 400 V on the APC Easy PDU Metered Zero U 22 kW, 230 1 phase on the APC NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet.

  • AC outlets quantity
    • Easy PDU Metered Zero U 22 kW:24 AC outlet(s)
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:40 AC outlet(s)
  • Nominal input voltage
    • Easy PDU Metered Zero U 22 kW:400 V
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:230 1 phase
  • Load capacity
    • Easy PDU Metered Zero U 22 kW:22080 VA
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:7400 VA
  • Number of phases
    • Easy PDU Metered Zero U 22 kW:3
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:1
  • Compliance certificates
    • Easy PDU Metered Zero U 22 kW:CE, UKCA
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:RoHS, REACH, WEEE
  • Operating temperature (T-T)
    • Easy PDU Metered Zero U 22 kW:-5 - 50 °C
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:23 - 140 °F
  • Operating altitude
    • Easy PDU Metered Zero U 22 kW:0 - 3000 m
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:0 - 3048 m
  • Depth
    • Easy PDU Metered Zero U 22 kW:56 mm
    • NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet:75 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of EPDU2232M, NetShelter Rack PDU Advanced Gen 2, Switched Metered Outlet, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlet
47 specifications
Designidentical
PDU typesMeteredMetered
TypeThree-phaseThree-phase
Rack capacity0U0U
Product colourBlackBlack
MountingKnown for oneVerticalUnknown — not stated by the source
Ports & interfaces2 differ
AC outlets quantityDiffers24 AC outlet(s)40 AC outlet(s)
AC outlet typesDiffersC13 coupler, C19 couplerC13 coupler, C15 coupler, C19 coupler, C21 coupler
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source5
USB ports quantityKnown for oneUnknown — not stated by the source1
Input connection typeKnown for oneUnknown — not stated by the sourceIEC 60309 32 A 2P + PE
Power plugKnown for oneC13 couplerUnknown — not stated by the source
Featuresidentical
Cable lengthKnown for oneUnknown — not stated by the source3 m
Management featuresidentical
Management platformKnown for oneUnknown — not stated by the sourceNMC3
Power3 differ
Nominal input voltageDiffers400 V230 1 phase
AC input frequency50/60 Hz50/60 Hz
Maximum current32 A32 A
Nominal output voltage230 V230 V
Output voltage230 V230 V
Load capacityDiffers22080 VA7400 VA
Number of phasesDiffers31
Battery replacement accessibilityKnown for oneUnknown — not stated by the sourceNon-removable
Certificates1 differ
Compliance certificatesDiffersCE, UKCARoHS, REACH, WEEE
Waste Electrical and Electronic Equipment (WEEE) complianceKnown for oneUnknown — not stated by the sourceYes
CertificationKnown for oneUnknown — not stated by the sourceUKCA
Operational conditions2 differ
Operating temperature (T-T)Differs-5 - 50 °C23 - 140 °F
Storage temperature (T-T)-25 - 65 °C-25 - 65 °C
Operating relative humidity (H-H)5 - 95%5 - 95%
Storage relative humidity (H-H)5 - 95%5 - 95%
Operating altitudeDiffers0 - 3000 m0 - 3048 m
Non-operating altitudeKnown for oneUnknown — not stated by the source0 - 15240 m
Weight & dimensions3 differ
Width56 mm56 mm
DepthDiffers56 mm75 mm
HeightDiffers1650 mm1490 mm
WeightDiffers4.85 kg7.5 kg
Packaging data4 differ
Package weightDiffers6.05 kg8.2 kg
Package widthDiffers170 mm116 mm
Package depthDiffers1810 mm208 mm
Package heightDiffers1260 mm1720 mm
Technical detailsidentical
Preferred mounting positionKnown for oneUnknown — not stated by the sourceno preference
Removable batteryKnown for oneUnknown — not stated by the sourceNo
Packaging without single use plasticKnown for oneUnknown — not stated by the sourceNo
SCIP numberKnown for oneUnknown — not stated by the source31346aed-552c-4a16-81d9-e683a383b6da
Sustainable packagingKnown for oneUnknown — not stated by the sourceNo
Take-back systemKnown for oneUnknown — not stated by the sourceNo
Logistics dataidentical
Country of originKnown for oneUnknown — not stated by the sourceUnited States
Customs product code (TARIC)Known for oneUnknown — not stated by the source8537109899
Total carbon footprint (kg of CO2e)Known for one1655Unknown — not stated by the source