Product comparison · 2 power distribution units (pdus)

APC EasyPDU, Switched, Zero U, 11 kW vs Vertiv Geist JMNS5MIZ1-24CF18-8HW15A9BXX-S power distribution unit (PDU) 24 AC outlet(s) 0U Black

Add a product
  • 16specifications compared
  • 9differ
  • 7identical
  • 24known for one product only

Key differences

The APC EasyPDU, Switched, Zero U, 11 kW has 192 V more nominal input voltage than the Vertiv Geist JMNS5MIZ1-24CF18-8HW15A9BXX-S power distribution unit (PDU) 24 AC outlet(s) 0U Black (400 V vs 208 V). The Vertiv Geist JMNS5MIZ1-24CF18-8HW15A9BXX-S power distribution unit (PDU) 24 AC outlet(s) 0U Black has 64 A more maximum current than the APC EasyPDU, Switched, Zero U, 11 kW (80 A vs 16 A). The APC EasyPDU, Switched, Zero U, 11 kW has 10,832 VA more load capacity than the Vertiv Geist JMNS5MIZ1-24CF18-8HW15A9BXX-S power distribution unit (PDU) 24 AC outlet(s) 0U Black (11040 VA vs 208 VA). AC outlets quantity: 27 AC outlet(s) on the APC EasyPDU, Switched, Zero U, 11 kW, 24 AC outlet(s) on the Vertiv Geist JMNS5MIZ1-24CF18-8HW15A9BXX-S power distribution unit (PDU) 24 AC outlet(s) 0U Black. Operating temperature (T-T): -5 - 50 °C on the APC EasyPDU, Switched, Zero U, 11 kW, 10 - 45 °C on the Vertiv Geist JMNS5MIZ1-24CF18-8HW15A9BXX-S power distribution unit (PDU) 24 AC outlet(s) 0U Black.

  • AC outlets quantity
    • EasyPDU, Switched, Zero U, 11 kW:27 AC outlet(s)
    • Geist JMNS5MIZ1-24CF18-8HW15A9BXX-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:24 AC outlet(s)
  • Nominal input voltage
    • EasyPDU, Switched, Zero U, 11 kW:400 V
    • Geist JMNS5MIZ1-24CF18-8HW15A9BXX-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:208 V
  • Maximum current
    • EasyPDU, Switched, Zero U, 11 kW:16 A
    • Geist JMNS5MIZ1-24CF18-8HW15A9BXX-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:80 A
  • Load capacity
    • EasyPDU, Switched, Zero U, 11 kW:11040 VA
    • Geist JMNS5MIZ1-24CF18-8HW15A9BXX-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:208 VA
  • Operating temperature (T-T)
    • EasyPDU, Switched, Zero U, 11 kW:-5 - 50 °C
    • Geist JMNS5MIZ1-24CF18-8HW15A9BXX-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:10 - 45 °C
  • Width
    • EasyPDU, Switched, Zero U, 11 kW:56 mm
    • Geist JMNS5MIZ1-24CF18-8HW15A9BXX-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:97 mm
  • Depth
    • EasyPDU, Switched, Zero U, 11 kW:62 mm
    • Geist JMNS5MIZ1-24CF18-8HW15A9BXX-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:76 mm
  • Height
    • EasyPDU, Switched, Zero U, 11 kW:1650 mm
    • Geist JMNS5MIZ1-24CF18-8HW15A9BXX-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:1683 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of EPDU2216S, JMNS5MIZ1-24CF18-8HW15A9BXX-S
40 specifications
Designidentical
PDU typesSwitchedSwitched
TypeThree-phaseThree-phase
Rack capacity0U0U
MountingVerticalVertical
Product colourBlackBlack
DisplayKnown for oneUnknown — not stated by the sourceLCD
Ports & interfaces1 differ
AC outlets quantityDiffers27 AC outlet(s)24 AC outlet(s)
Power plugKnown for oneC13 couplerUnknown — not stated by the source
AC outlet typesC13 coupler, C19 couplerC13 coupler, C19 coupler
Serial ports quantityKnown for oneUnknown — not stated by the source1
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source1
USB ports quantityKnown for oneUnknown — not stated by the source1
Power3 differ
Nominal input voltageDiffers400 V208 V
AC input frequency50/60 Hz50/60 Hz
Maximum currentDiffers16 A80 A
Nominal output voltageKnown for one230 VUnknown — not stated by the source
Output voltageKnown for one230 VUnknown — not stated by the source
Load capacityDiffers11040 VA208 VA
Number of phasesKnown for one3Unknown — not stated by the source
Power protection featuresKnown for oneUnknown — not stated by the sourceOver current
Certificatesidentical
Compliance certificatesKnown for oneCE, UKCAUnknown — not stated by the source
CertificationKnown for oneUnknown — not stated by the sourceUL & c-UL Listed 62368-1 RoHS Compliant FCC Part 15 Class A Conformance
Operational conditions1 differ
Operating temperature (T-T)Differs-5 - 50 °C10 - 45 °C
Storage temperature (T-T)Known for one-25 - 65 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers56 mm97 mm
DepthDiffers62 mm76 mm
HeightDiffers1650 mm1683 mm
WeightDiffers6.2 kg9.98 kg
Packaging dataidentical
Package weightKnown for one7.7 kgUnknown — not stated by the source
Package widthKnown for one170 mmUnknown — not stated by the source
Package depthKnown for one1810 mmUnknown — not stated by the source
Package heightKnown for one1260 mmUnknown — not stated by the source
Logistics dataidentical
Total carbon footprint (kg of CO2e)Known for one1462Unknown — not stated by the source
Featuresidentical
Reset buttonKnown for oneUnknown — not stated by the sourceYes
LED indicatorsKnown for oneUnknown — not stated by the sourceYes
Cable lengthKnown for oneUnknown — not stated by the source3.05 m
Management featuresidentical
Supported network protocolsKnown for oneUnknown — not stated by the sourceDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+, Modbus TCP

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.