Product comparison · 2 power distribution units (pdus)

APC EasyPDU, Switched, Zero U, 11 kW vs APC NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets

Add a product
  • 22specifications compared
  • 15differ
  • 7identical
  • 24known for one product only

Key differences

The APC NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets has 16 A more maximum current than the APC EasyPDU, Switched, Zero U, 11 kW (32 A vs 16 A). The APC EasyPDU, Switched, Zero U, 11 kW has 3,640 VA more load capacity than the APC NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets (11040 VA vs 7400 VA). The APC EasyPDU, Switched, Zero U, 11 kW has 2 more phases than the APC NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets (3 vs 1). PDU types: Switched on the APC EasyPDU, Switched, Zero U, 11 kW, Metered on the APC NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets. Type: Three-phase on the APC EasyPDU, Switched, Zero U, 11 kW, Single-phase on the APC NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets.

  • PDU types
    • EasyPDU, Switched, Zero U, 11 kW:Switched
    • NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets:Metered
  • Type
    • EasyPDU, Switched, Zero U, 11 kW:Three-phase
    • NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets:Single-phase
  • AC outlets quantity
    • EasyPDU, Switched, Zero U, 11 kW:27 AC outlet(s)
    • NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets:40 AC outlet(s)
  • Nominal input voltage
    • EasyPDU, Switched, Zero U, 11 kW:400 V
    • NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets:230 1 phase
  • Maximum current
    • EasyPDU, Switched, Zero U, 11 kW:16 A
    • NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets:32 A
  • Load capacity
    • EasyPDU, Switched, Zero U, 11 kW:11040 VA
    • NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets:7400 VA
  • Number of phases
    • EasyPDU, Switched, Zero U, 11 kW:3
    • NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets:1
  • Compliance certificates
    • EasyPDU, Switched, Zero U, 11 kW:CE, UKCA
    • NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets:RoHS, REACH, WEEE

Side by side

Differences highlightedShow differences only (off)
Comparison of EPDU2216S, NetShelter Rack PDU Advanced Gen 2, Metered, 7.4kW, 1Phase, 230V, 32A, 332P6, 40 Outlets
46 specifications
Design2 differ
PDU typesDiffersSwitchedMetered
TypeDiffersThree-phaseSingle-phase
Rack capacity0U0U
Product colourBlackBlack
MountingKnown for oneVerticalUnknown — not stated by the source
Ports & interfaces2 differ
AC outlets quantityDiffers27 AC outlet(s)40 AC outlet(s)
AC outlet typesDiffersC13 coupler, C19 couplerC13 coupler, C15 coupler, C19 coupler, C21 coupler
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source5
USB ports quantityKnown for oneUnknown — not stated by the source1
Input connection typeKnown for oneUnknown — not stated by the sourceIEC 60309 32 A 2P + PE
Power plugKnown for oneC13 couplerUnknown — not stated by the source
Featuresidentical
Cable lengthKnown for oneUnknown — not stated by the source3 m
Management featuresidentical
Management platformKnown for oneUnknown — not stated by the sourceNMC3
Power4 differ
Nominal input voltageDiffers400 V230 1 phase
AC input frequency50/60 Hz50/60 Hz
Maximum currentDiffers16 A32 A
Nominal output voltage230 V230 V
Output voltage230 V230 V
Load capacityDiffers11040 VA7400 VA
Number of phasesDiffers31
Battery replacement accessibilityKnown for oneUnknown — not stated by the sourceNon-removable
Certificates1 differ
Compliance certificatesDiffersCE, UKCARoHS, REACH, WEEE
Waste Electrical and Electronic Equipment (WEEE) complianceKnown for oneUnknown — not stated by the sourceYes
CertificationKnown for oneUnknown — not stated by the sourceUKCA
Weight & dimensions2 differ
Width56 mm56 mm
DepthDiffers62 mm75 mm
HeightDiffers1650 mm1490 mm
Weight6.2 kg6.2 kg
Packaging data4 differ
Package weightDiffers7.7 kg8.2 kg
Package widthDiffers170 mm116 mm
Package depthDiffers1810 mm208 mm
Package heightDiffers1260 mm1720 mm
Technical detailsidentical
Preferred mounting positionKnown for oneUnknown — not stated by the sourceno preference
Removable batteryKnown for oneUnknown — not stated by the sourceNo
Packaging without single use plasticKnown for oneUnknown — not stated by the sourceNo
SCIP numberKnown for oneUnknown — not stated by the source31346aed-552c-4a16-81d9-e683a383b6da
Sustainable packagingKnown for oneUnknown — not stated by the sourceNo
Take-back systemKnown for oneUnknown — not stated by the sourceNo
Logistics dataidentical
Country of originKnown for oneUnknown — not stated by the sourceUnited States
Customs product code (TARIC)Known for oneUnknown — not stated by the source8537109899
Total carbon footprint (kg of CO2e)Known for one1462Unknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)Known for one-5 - 50 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-25 - 65 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons