Product comparison · 2 power distribution units (pdus)

APC Easy PDU Metered Zero U 11 kW vs Lanview LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black

Add a product
  • 20specifications compared
  • 18differ
  • 2identical
  • 19known for one product only

Key differences

The Lanview LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black has 1 U more rack capacity than the APC Easy PDU Metered Zero U 11 kW (1U vs 0U). The APC Easy PDU Metered Zero U 11 kW has 170 V more nominal input voltage than the Lanview LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black (400 V vs 230 V). The APC Easy PDU Metered Zero U 11 kW has 2 more phases than the Lanview LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black (3 vs 1). PDU types: Metered on the APC Easy PDU Metered Zero U 11 kW, Basic on the Lanview LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black. Type: Three-phase on the APC Easy PDU Metered Zero U 11 kW, Single-phase on the Lanview LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black.

  • PDU types
    • Easy PDU Metered Zero U 11 kW:Metered
    • LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black:Basic
  • Type
    • Easy PDU Metered Zero U 11 kW:Three-phase
    • LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black:Single-phase
  • Rack capacity
    • Easy PDU Metered Zero U 11 kW:0U
    • LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black:1U
  • Mounting
    • Easy PDU Metered Zero U 11 kW:Vertical
    • LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black:Horizontal
  • AC outlets quantity
    • Easy PDU Metered Zero U 11 kW:21 AC outlet(s)
    • LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black:8 AC outlet(s)
  • Power plug
    • Easy PDU Metered Zero U 11 kW:C13 coupler
    • LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black:Type F
  • AC outlet types
    • Easy PDU Metered Zero U 11 kW:C13 coupler, C19 coupler
    • LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black:Type F
  • Nominal input voltage
    • Easy PDU Metered Zero U 11 kW:400 V
    • LVR-2MSCH-SPD-SCH8 power distribution unit (PDU) 8 AC outlet(s) 1U Black:230 V

Side by side

Differences highlightedShow differences only (on)
Comparison of EPDU2216M, LVR-2MSCH-SPD-SCH8
39 specifications
Design4 differ
PDU typesDiffersMeteredBasic
TypeDiffersThree-phaseSingle-phase
Rack capacityDiffers0U1U
MountingDiffersVerticalHorizontal
Rack mountingKnown for oneUnknown — not stated by the sourceYes
Housing materialKnown for oneUnknown — not stated by the sourceAluminium
Cable colourKnown for oneUnknown — not stated by the sourceBlack
On/off switchKnown for oneUnknown — not stated by the sourceNo
Ports & interfaces3 differ
AC outlets quantityDiffers21 AC outlet(s)8 AC outlet(s)
Power plugDiffersC13 couplerType F
AC outlet typesDiffersC13 coupler, C19 couplerType F
Power2 differ
Nominal input voltageDiffers400 V230 V
AC input frequencyKnown for one50/60 HzUnknown — not stated by the source
Nominal output voltageKnown for one230 VUnknown — not stated by the source
Output voltageKnown for one230 VUnknown — not stated by the source
Load capacityKnown for one11040 VAUnknown — not stated by the source
Number of phasesDiffers31
Maximum powerKnown for oneUnknown — not stated by the source4000 W
Surge protectionKnown for oneUnknown — not stated by the sourceYes
Certificates1 differ
Compliance certificatesDiffersCE, UKCARoHS
Operational conditionsidentical
Operating temperature (T-T)Known for one-5 - 50 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-25 - 65 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers56 mm570 mm
DepthDiffers56 mm95 mm
HeightDiffers1650 mm55 mm
WeightDiffers3.3 kg1.2 kg
Packaging data4 differ
Package weightDiffers4.5 kg1.4 kg
Package widthDiffers170 mm570 mm
Package depthDiffers1810 mm95 mm
Package heightDiffers1260 mm55 mm
Logistics dataidentical
Total carbon footprint (kg of CO2e)Known for one1239Unknown — not stated by the source
Quantity per packKnown for oneUnknown — not stated by the source1 pc(s)
Featuresidentical
Cable lengthKnown for oneUnknown — not stated by the source3 m
Cable typeKnown for oneUnknown — not stated by the sourceH05VV-F 3X1.5mm2

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons

All power distribution units (pdus) comparisons