Product comparison · 2 power distribution units (pdus)

APC Easy PDU Metered Zero U 11 kW vs APC NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets

Add a product
  • 27specifications compared
  • 22differ
  • 5identical
  • 16known for one product only

Key differences

The APC NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets has 2 U more rack capacity than the APC Easy PDU Metered Zero U 11 kW (2U vs 0U). The APC NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets has 44 A more maximum current than the APC Easy PDU Metered Zero U 11 kW (60 A vs 16 A). The APC NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets has 30,360 VA more load capacity than the APC Easy PDU Metered Zero U 11 kW (41400 VA vs 11040 VA). PDU types: Metered on the APC Easy PDU Metered Zero U 11 kW, Metered-by-outlet on the APC NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets. Mounting: Vertical on the APC Easy PDU Metered Zero U 11 kW, Horizontal on the APC NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets.

  • PDU types
    • Easy PDU Metered Zero U 11 kW:Metered
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:Metered-by-outlet
  • Rack capacity
    • Easy PDU Metered Zero U 11 kW:0U
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:2U
  • Mounting
    • Easy PDU Metered Zero U 11 kW:Vertical
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:Horizontal
  • AC outlets quantity
    • Easy PDU Metered Zero U 11 kW:21 AC outlet(s)
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:18 AC outlet(s)
  • Power plug
    • Easy PDU Metered Zero U 11 kW:C13 coupler
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:IEC309
  • Nominal input voltage
    • Easy PDU Metered Zero U 11 kW:400 V
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:415 3 phases
  • Maximum current
    • Easy PDU Metered Zero U 11 kW:16 A
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:60 A
  • Output voltage
    • Easy PDU Metered Zero U 11 kW:230 V
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:415 V AC 3 phases

Side by side

Differences highlightedShow differences only (off)
Comparison of EPDU2216M, NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets
43 specifications
Design3 differ
PDU typesDiffersMeteredMetered-by-outlet
TypeThree-phaseThree-phase
Rack capacityDiffers0U2U
MountingDiffersVerticalHorizontal
Product colourBlackBlack
UpgradeableKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces3 differ
AC outlets quantityDiffers21 AC outlet(s)18 AC outlet(s)
Power plugDiffersC13 couplerIEC309
AC outlet typesDiffersC13 coupler, C19 couplerC13 coupler, C15 coupler, C19 coupler, C21 coupler
Input connection typeKnown for oneUnknown — not stated by the sourceIEC 309 60 A
Featuresidentical
International Protection (IP) codeKnown for oneUnknown — not stated by the sourceIP44
Management featuresidentical
Management platformKnown for oneUnknown — not stated by the sourceNMC3
Power4 differ
Nominal input voltageDiffers400 V415 3 phases
AC input frequency50/60 Hz50/60 Hz
Maximum currentDiffers16 A60 A
Output voltageDiffers230 V415 V AC 3 phases
Load capacityDiffers11040 VA41400 VA
Number of phases33
Nominal output voltageKnown for one230 VUnknown — not stated by the source
Certificates1 differ
Compliance certificatesDiffersCE, UKCARoHS, REACH, WEEE
Waste Electrical and Electronic Equipment (WEEE) complianceKnown for oneUnknown — not stated by the sourceYes
Sustainabilityidentical
Doesn't containKnown for oneUnknown — not stated by the sourceSilicone
Operational conditions3 differ
Operating temperature (T-T)Differs-5 - 50 °C-5 - 60 °C
Storage temperature (T-T)Differs-25 - 65 °C-20 - 60 °C
Operating relative humidity (H-H)Differs5 - 95%5 - 90%
Storage relative humidity (H-H)5 - 95%5 - 95%
Non-operating altitudeKnown for oneUnknown — not stated by the source0 - 15240 m
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers56 mm443 mm
DepthDiffers56 mm750 mm
HeightDiffers1650 mm85 mm
WeightDiffers3.3 kg16.3 kg
Packaging data4 differ
Package weightDiffers4.5 kg22.8 kg
Package widthDiffers170 mm600 mm
Package depthDiffers1810 mm165 mm
Package heightDiffers1260 mm940 mm
Technical detailsidentical
Packaging recycled materialsKnown for oneUnknown — not stated by the sourceRecycled cardboard
Preferred mounting positionKnown for oneUnknown — not stated by the sourceno preference
Packaging without single use plasticKnown for oneUnknown — not stated by the sourceYes
SCIP numberKnown for oneUnknown — not stated by the source7547f066-9302-46d9-96e9-461928dd6901
Sustainable packagingKnown for oneUnknown — not stated by the sourceNo
Take-back systemKnown for oneUnknown — not stated by the sourceNo
Logistics dataidentical
Total carbon footprint (kg of CO2e)Known for one1239Unknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.