Product comparison · 2 power distribution units (pdus)

APC Easy PDU Metered Zero U 32A vs APC NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet

Add a product
  • 22specifications compared
  • 17differ
  • 5identical
  • 23known for one product only

Key differences

The APC Easy PDU Metered Zero U 32A has 12 A more maximum current than the APC NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet (32 A vs 20 A). The APC NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet has 170 V more nominal output voltage than the APC Easy PDU Metered Zero U 32A (400 V vs 230 V). The APC NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet has 10 V more output voltage than the APC Easy PDU Metered Zero U 32A (240 V vs 230 V). Type: Single-phase on the APC Easy PDU Metered Zero U 32A, Three-phase on the APC NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet. AC outlets quantity: 24 AC outlet(s) on the APC Easy PDU Metered Zero U 32A, 40 AC outlet(s) on the APC NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet.

  • Type
    • Easy PDU Metered Zero U 32A:Single-phase
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:Three-phase
  • AC outlets quantity
    • Easy PDU Metered Zero U 32A:24 AC outlet(s)
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:40 AC outlet(s)
  • Nominal input voltage
    • Easy PDU Metered Zero U 32A:230 V
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:415 3 phases; 400 3 phases
  • Maximum current
    • Easy PDU Metered Zero U 32A:32 A
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:20 A
  • Nominal output voltage
    • Easy PDU Metered Zero U 32A:230 V
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:400 V
  • Output voltage
    • Easy PDU Metered Zero U 32A:230 V
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:240 V
  • Load capacity
    • Easy PDU Metered Zero U 32A:7360 VA
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:11500 VA
  • Number of phases
    • Easy PDU Metered Zero U 32A:1
    • NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet:3

Side by side

Differences highlightedShow differences only (off)
Comparison of EPDU2132M, NetShelter Rack PDU Advanced Gen 2, Metered, 3Phase, 11kW 400V 16A or 11.5kW 415V 20A, 520P6, 42 Outlet
45 specifications
Design1 differ
PDU typesMeteredMetered
TypeDiffersSingle-phaseThree-phase
Rack capacity0U0U
Product colourBlackBlack
MountingKnown for oneVerticalUnknown — not stated by the source
Ports & interfaces2 differ
AC outlets quantityDiffers24 AC outlet(s)40 AC outlet(s)
AC outlet typesDiffersC13 couplerC13 coupler, C15 coupler, C19 coupler, C21 coupler
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source5
USB ports quantityKnown for oneUnknown — not stated by the source1
Input connection typeKnown for oneUnknown — not stated by the sourceIEC 60309 20 A 3P + N + PE
Power plugKnown for oneIEC309Unknown — not stated by the source
Featuresidentical
Cable lengthKnown for oneUnknown — not stated by the source3 m
Management featuresidentical
Management platformKnown for oneUnknown — not stated by the sourceNMC3
Power6 differ
Nominal input voltageDiffers230 V415 3 phases; 400 3 phases
AC input frequency50/60 Hz50/60 Hz
Maximum currentDiffers32 A20 A
Nominal output voltageDiffers230 V400 V
Output voltageDiffers230 V240 V
Load capacityDiffers7360 VA11500 VA
Number of phasesDiffers13
Battery replacement accessibilityKnown for oneUnknown — not stated by the sourceNon-removable
Certificates1 differ
Compliance certificatesDiffersCE, UKCARoHS, REACH, WEEE
Waste Electrical and Electronic Equipment (WEEE) complianceKnown for oneUnknown — not stated by the sourceYes
CertificationKnown for oneUnknown — not stated by the sourceUKCA
Weight & dimensions3 differ
Width56 mm56 mm
DepthDiffers56 mm55 mm
HeightDiffers1400 mm1490 mm
WeightDiffers3.35 kg5.7 kg
Packaging data4 differ
Package weightDiffers4.35 kg8.2 kg
Package widthDiffers260 mm116 mm
Package depthDiffers1560 mm208 mm
Package heightDiffers680 mm1720 mm
Technical detailsidentical
Preferred mounting positionKnown for oneUnknown — not stated by the sourceno preference
Removable batteryKnown for oneUnknown — not stated by the sourceNo
Packaging without single use plasticKnown for oneUnknown — not stated by the sourceNo
SCIP numberKnown for oneUnknown — not stated by the source31346aed-552c-4a16-81d9-e683a383b6da
Sustainable packagingKnown for oneUnknown — not stated by the sourceNo
Take-back systemKnown for oneUnknown — not stated by the sourceNo
Logistics dataidentical
Customs product code (TARIC)Known for oneUnknown — not stated by the source8537109899
Total carbon footprint (kg of CO2e)Known for one806Unknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)Known for one-5 - 50 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-25 - 65 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.