Product comparison · 2 power distribution units (pdus)

APC Easy PDU Switched ZeroU 16A vs APC NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets

Add a product
  • 27specifications compared
  • 23differ
  • 4identical
  • 16known for one product only

Key differences

The APC NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets has 2 U more rack capacity than the APC Easy PDU Switched ZeroU 16A (2U vs 0U). The APC NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets has 44 A more maximum current than the APC Easy PDU Switched ZeroU 16A (60 A vs 16 A). The APC NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets has 37,720 VA more load capacity than the APC Easy PDU Switched ZeroU 16A (41400 VA vs 3680 VA). Type: Single-phase on the APC Easy PDU Switched ZeroU 16A, Three-phase on the APC NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets. Mounting: Vertical on the APC Easy PDU Switched ZeroU 16A, Horizontal on the APC NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets.

  • Type
    • Easy PDU Switched ZeroU 16A:Single-phase
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:Three-phase
  • Rack capacity
    • Easy PDU Switched ZeroU 16A:0U
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:2U
  • Mounting
    • Easy PDU Switched ZeroU 16A:Vertical
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:Horizontal
  • AC outlets quantity
    • Easy PDU Switched ZeroU 16A:24 AC outlet(s)
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:18 AC outlet(s)
  • Power plug
    • Easy PDU Switched ZeroU 16A:IEC 60309
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:IEC309
  • Nominal input voltage
    • Easy PDU Switched ZeroU 16A:230 V
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:415 3 phases
  • Maximum current
    • Easy PDU Switched ZeroU 16A:16 A
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:60 A
  • Output voltage
    • Easy PDU Switched ZeroU 16A:230 V
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:415 V AC 3 phases

Side by side

Differences highlightedShow differences only (off)
Comparison of EPDU2116S, NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets
43 specifications
Design3 differ
PDU typesSwitchedSwitched
TypeDiffersSingle-phaseThree-phase
Rack capacityDiffers0U2U
MountingDiffersVerticalHorizontal
Product colourBlackBlack
UpgradeableKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces3 differ
AC outlets quantityDiffers24 AC outlet(s)18 AC outlet(s)
Power plugDiffersIEC 60309IEC309
AC outlet typesDiffersC13 couplerC13 coupler, C15 coupler, C19 coupler, C21 coupler
Input connection typeKnown for oneUnknown — not stated by the sourceIEC 309 60 A
Featuresidentical
International Protection (IP) codeKnown for oneUnknown — not stated by the sourceIP44
Management featuresidentical
Management platformKnown for oneUnknown — not stated by the sourceNMC3
Power5 differ
Nominal input voltageDiffers230 V415 3 phases
AC input frequency50/60 Hz50/60 Hz
Maximum currentDiffers16 A60 A
Output voltageDiffers230 V415 V AC 3 phases
Load capacityDiffers3680 VA41400 VA
Number of phasesDiffers13
Nominal output voltageKnown for one230 VUnknown — not stated by the source
Certificates1 differ
Compliance certificatesDiffersCE, UKCARoHS, REACH, WEEE
Waste Electrical and Electronic Equipment (WEEE) complianceKnown for oneUnknown — not stated by the sourceYes
Sustainabilityidentical
Doesn't containKnown for oneUnknown — not stated by the sourceSilicone
Operational conditions3 differ
Operating temperature (T-T)Differs-5 - 50 °C-5 - 60 °C
Storage temperature (T-T)Differs-25 - 65 °C-20 - 60 °C
Operating relative humidity (H-H)Differs5 - 95%5 - 90%
Storage relative humidity (H-H)5 - 95%5 - 95%
Non-operating altitudeKnown for oneUnknown — not stated by the source0 - 15240 m
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers56 mm443 mm
DepthDiffers62 mm750 mm
HeightDiffers1650 mm85 mm
WeightDiffers6.1 kg16 kg
Packaging data4 differ
Package weightDiffers7.6 kg22.5 kg
Package widthDiffers170 mm600 mm
Package depthDiffers1810 mm165 mm
Package heightDiffers1260 mm940 mm
Technical detailsidentical
Packaging recycled materialsKnown for oneUnknown — not stated by the sourceRecycled cardboard
Preferred mounting positionKnown for oneUnknown — not stated by the sourceno preference
Packaging without single use plasticKnown for oneUnknown — not stated by the sourceYes
SCIP numberKnown for oneUnknown — not stated by the source7547f066-9302-46d9-96e9-461928dd6901
Sustainable packagingKnown for oneUnknown — not stated by the sourceNo
Take-back systemKnown for oneUnknown — not stated by the sourceNo
Logistics dataidentical
Total carbon footprint (kg of CO2e)Known for one1088Unknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.