The APC Easy PDU Metered Zero U 11 kW has 170 V more nominal input voltage than the APC Easy PDU Switched ZeroU 16A (400 V vs 230 V). The APC Easy PDU Metered Zero U 11 kW has 7,360 VA more load capacity than the APC Easy PDU Switched ZeroU 16A (11040 VA vs 3680 VA). The APC Easy PDU Metered Zero U 11 kW has 2 more phases than the APC Easy PDU Switched ZeroU 16A (3 vs 1). PDU types: Switched on the APC Easy PDU Switched ZeroU 16A, Metered on the APC Easy PDU Metered Zero U 11 kW. Type: Single-phase on the APC Easy PDU Switched ZeroU 16A, Three-phase on the APC Easy PDU Metered Zero U 11 kW.

  • PDU types
    • Easy PDU Switched ZeroU 16A:Switched
    • Easy PDU Metered Zero U 11 kW:Metered
  • Type
    • Easy PDU Switched ZeroU 16A:Single-phase
    • Easy PDU Metered Zero U 11 kW:Three-phase
  • AC outlets quantity
    • Easy PDU Switched ZeroU 16A:24 AC outlet(s)
    • Easy PDU Metered Zero U 11 kW:21 AC outlet(s)
  • Power plug
    • Easy PDU Switched ZeroU 16A:IEC 60309
    • Easy PDU Metered Zero U 11 kW:C13 coupler
  • AC outlet types
    • Easy PDU Switched ZeroU 16A:C13 coupler
    • Easy PDU Metered Zero U 11 kW:C13 coupler, C19 coupler
  • Nominal input voltage
    • Easy PDU Switched ZeroU 16A:230 V
    • Easy PDU Metered Zero U 11 kW:400 V
  • Load capacity
    • Easy PDU Switched ZeroU 16A:3680 VA
    • Easy PDU Metered Zero U 11 kW:11040 VA
  • Number of phases
    • Easy PDU Switched ZeroU 16A:1
    • Easy PDU Metered Zero U 11 kW:3

Side by side

Differences highlightedShow differences only (on)
Comparison of EPDU2116S, EPDU2216M
30 specifications
Design2 differ
PDU typesDiffersSwitchedMetered
TypeDiffersSingle-phaseThree-phase
Ports & interfaces3 differ
AC outlets quantityDiffers24 AC outlet(s)21 AC outlet(s)
Power plugDiffersIEC 60309C13 coupler
AC outlet typesDiffersC13 couplerC13 coupler, C19 coupler
Power3 differ
Nominal input voltageDiffers230 V400 V
Load capacityDiffers3680 VA11040 VA
Number of phasesDiffers13
Weight & dimensions2 differ
DepthDiffers62 mm56 mm
WeightDiffers6.1 kg3.3 kg
Packaging data1 differ
Package weightDiffers7.6 kg4.5 kg
Logistics data1 differ
Total carbon footprint (kg of CO2e)Differs10881239