Product comparison · 2 power distribution units (pdus)

APC Easy PDU Switched ZeroU 16A vs APC Easy PDU Switched Zero U 32A

Add a product
  • 30specifications compared
  • 6differ
  • 24identical
  • 0known for one product only

Key differences

The APC Easy PDU Switched Zero U 32A has 16 A more maximum current than the APC Easy PDU Switched ZeroU 16A (32 A vs 16 A). The APC Easy PDU Switched Zero U 32A has 3,680 VA more load capacity than the APC Easy PDU Switched ZeroU 16A (7360 VA vs 3680 VA). The APC Easy PDU Switched Zero U 32A has 0.55 kg more weight than the APC Easy PDU Switched ZeroU 16A (6.65 kg vs 6.1 kg). AC outlets quantity: 24 AC outlet(s) on the APC Easy PDU Switched ZeroU 16A, 17 AC outlet(s) on the APC Easy PDU Switched Zero U 32A.

  • AC outlets quantity
    • Easy PDU Switched ZeroU 16A:24 AC outlet(s)
    • Easy PDU Switched Zero U 32A:17 AC outlet(s)
  • Maximum current
    • Easy PDU Switched ZeroU 16A:16 A
    • Easy PDU Switched Zero U 32A:32 A
  • Load capacity
    • Easy PDU Switched ZeroU 16A:3680 VA
    • Easy PDU Switched Zero U 32A:7360 VA
  • Weight
    • Easy PDU Switched ZeroU 16A:6.1 kg
    • Easy PDU Switched Zero U 32A:6.65 kg
  • Package weight
    • Easy PDU Switched ZeroU 16A:7.6 kg
    • Easy PDU Switched Zero U 32A:8.15 kg
  • Total carbon footprint (kg of CO2e)
    • Easy PDU Switched ZeroU 16A:1088
    • Easy PDU Switched Zero U 32A:1310

Side by side

Differences highlightedShow differences only (off)
Comparison of EPDU2116S, EPDU2132S
30 specifications
Designidentical
PDU typesSwitchedSwitched
TypeSingle-phaseSingle-phase
Rack capacity0U0U
MountingVerticalVertical
Product colourBlackBlack
Ports & interfaces1 differ
AC outlets quantityDiffers24 AC outlet(s)17 AC outlet(s)
Power plugIEC 60309IEC 60309
AC outlet typesC13 couplerC13 coupler
Power2 differ
Nominal input voltage230 V230 V
AC input frequency50/60 Hz50/60 Hz
Maximum currentDiffers16 A32 A
Nominal output voltage230 V230 V
Output voltage230 V230 V
Load capacityDiffers3680 VA7360 VA
Number of phases11
Certificatesidentical
Compliance certificatesCE, UKCACE, UKCA
Operational conditionsidentical
Operating temperature (T-T)-5 - 50 °C-5 - 50 °C
Storage temperature (T-T)-25 - 65 °C-25 - 65 °C
Operating relative humidity (H-H)5 - 95%5 - 95%
Storage relative humidity (H-H)5 - 95%5 - 95%
Operating altitude0 - 3000 m0 - 3000 m
Weight & dimensions1 differ
Width56 mm56 mm
Depth62 mm62 mm
Height1650 mm1650 mm
WeightDiffers6.1 kg6.65 kg
Packaging data1 differ
Package weightDiffers7.6 kg8.15 kg
Package width170 mm170 mm
Package depth1810 mm1810 mm
Package height1260 mm1260 mm
Logistics data1 differ
Total carbon footprint (kg of CO2e)Differs10881310