Product comparison · 2 power distribution units (pdus)

APC Easy PDU Metered ZeroU 16A vs ATEN 32A 8-Outlet 1U Outlet Metered & Switched PDU + Free Eco PDU Manager Software

Add a product
  • 22specifications compared
  • 18differ
  • 4identical
  • 22known for one product only

Key differences

The ATEN 32A 8-Outlet 1U Outlet Metered & Switched PDU + Free Eco PDU Manager Software has 1 U more rack capacity than the APC Easy PDU Metered ZeroU 16A (1U vs 0U). The ATEN 32A 8-Outlet 1U Outlet Metered & Switched PDU + Free Eco PDU Manager Software has 16 A more maximum current than the APC Easy PDU Metered ZeroU 16A (32 A vs 16 A). The ATEN 32A 8-Outlet 1U Outlet Metered & Switched PDU + Free Eco PDU Manager Software has 4,000 VA more load capacity than the APC Easy PDU Metered ZeroU 16A (7680 VA vs 3680 VA). PDU types: Metered on the APC Easy PDU Metered ZeroU 16A, Metered, Switched on the ATEN 32A 8-Outlet 1U Outlet Metered & Switched PDU + Free Eco PDU Manager Software. Mounting: Vertical on the APC Easy PDU Metered ZeroU 16A, Horizontal on the ATEN 32A 8-Outlet 1U Outlet Metered & Switched PDU + Free Eco PDU Manager Software.

  • PDU types
    • Easy PDU Metered ZeroU 16A:Metered
    • 32A 8-Outlet 1U Outlet Metered & Switched PDU + Free Eco PDU Manager Software:Metered, Switched
  • Rack capacity
    • Easy PDU Metered ZeroU 16A:0U
    • 32A 8-Outlet 1U Outlet Metered & Switched PDU + Free Eco PDU Manager Software:1U
  • Mounting
    • Easy PDU Metered ZeroU 16A:Vertical
    • 32A 8-Outlet 1U Outlet Metered & Switched PDU + Free Eco PDU Manager Software:Horizontal
  • AC outlets quantity
    • Easy PDU Metered ZeroU 16A:21 AC outlet(s)
    • 32A 8-Outlet 1U Outlet Metered & Switched PDU + Free Eco PDU Manager Software:8 AC outlet(s)
  • AC outlet types
    • Easy PDU Metered ZeroU 16A:C13 coupler
    • 32A 8-Outlet 1U Outlet Metered & Switched PDU + Free Eco PDU Manager Software:C13 coupler, C19 coupler
  • Nominal input voltage
    • Easy PDU Metered ZeroU 16A:230 V
    • 32A 8-Outlet 1U Outlet Metered & Switched PDU + Free Eco PDU Manager Software:100 - 240 V
  • AC input frequency
    • Easy PDU Metered ZeroU 16A:50/60 Hz
    • 32A 8-Outlet 1U Outlet Metered & Switched PDU + Free Eco PDU Manager Software:50-60 Hz
  • Maximum current
    • Easy PDU Metered ZeroU 16A:16 A
    • 32A 8-Outlet 1U Outlet Metered & Switched PDU + Free Eco PDU Manager Software:32 A

Side by side

Differences highlightedShow differences only (off)
Comparison of EPDU2116M, PG8308G
44 specifications
Design3 differ
PDU typesDiffersMeteredMetered, Switched
TypeSingle-phaseSingle-phase
Rack capacityDiffers0U1U
MountingDiffersVerticalHorizontal
Housing materialKnown for oneUnknown — not stated by the sourceMetal
Product colourBlackBlack
DisplayKnown for oneUnknown — not stated by the sourceLCD
Ports & interfaces2 differ
AC outlets quantityDiffers21 AC outlet(s)8 AC outlet(s)
Power plugIEC 60309IEC 60309
AC outlet typesDiffersC13 couplerC13 coupler, C19 coupler
Serial ports quantityKnown for oneUnknown — not stated by the source1
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source2
USB ports quantityKnown for oneUnknown — not stated by the source1
Featuresidentical
Daisy chainKnown for oneUnknown — not stated by the sourceYes
Reset buttonKnown for oneUnknown — not stated by the sourceYes
LED indicatorsKnown for oneUnknown — not stated by the sourceYes
Cable lengthKnown for oneUnknown — not stated by the source3 m
Compatible productsKnown for oneUnknown — not stated by the sourceECO-DC
Management featuresidentical
MonitoringKnown for oneUnknown — not stated by the sourceCurrent, Voltage
Management platformKnown for oneUnknown — not stated by the sourceECO-DC
Power6 differ
Nominal input voltageDiffers230 V100 - 240 V
AC input frequencyDiffers50/60 Hz50-60 Hz
Maximum currentDiffers16 A32 A
Nominal output voltageDiffers230 V100-240 V
Output voltageDiffers230 V100 - 240 V
Load capacityDiffers3680 VA7680 VA
Number of phasesKnown for one1Unknown — not stated by the source
Certificatesidentical
Compliance certificatesCE, UKCACE, UKCA
CertificationKnown for oneUnknown — not stated by the sourceCE, UKCA
Operational conditions3 differ
Operating temperature (T-T)Differs-5 - 50 °C0 - 60 °C
Storage temperature (T-T)Differs-25 - 65 °C-20 - 60 °C
Operating relative humidity (H-H)Differs5 - 95%0 - 80%
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers56 mm210 mm
DepthDiffers56 mm432.4 mm
HeightDiffers1400 mm44 mm
WeightDiffers3.05 kg4.07 kg
Logistics dataidentical
Country of originKnown for oneUnknown — not stated by the sourceTaiwan
Total carbon footprint (kg of CO2e)Known for one580Unknown — not stated by the source
Packaging dataidentical
Package weightKnown for one4.05 kgUnknown — not stated by the source
Package widthKnown for one260 mmUnknown — not stated by the source
Package depthKnown for one1560 mmUnknown — not stated by the source
Package heightKnown for one680 mmUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.