Product comparison · 2 power distribution units (pdus)

APC Easy PDU Switched 1U 16A vs APC Easy PDU Metered Zero U 11 kW

Add a product
  • 29specifications compared
  • 19differ
  • 10identical
  • 1known for one product only

Key differences

The APC Easy PDU Switched 1U 16A has 1 U more rack capacity than the APC Easy PDU Metered Zero U 11 kW (1U vs 0U). The APC Easy PDU Metered Zero U 11 kW has 170 V more nominal input voltage than the APC Easy PDU Switched 1U 16A (400 V vs 230 V). The APC Easy PDU Metered Zero U 11 kW has 22 V more output voltage than the APC Easy PDU Switched 1U 16A (230 V vs 208 V). PDU types: Switched on the APC Easy PDU Switched 1U 16A, Metered on the APC Easy PDU Metered Zero U 11 kW. Type: Single-phase on the APC Easy PDU Switched 1U 16A, Three-phase on the APC Easy PDU Metered Zero U 11 kW.

  • PDU types
    • Easy PDU Switched 1U 16A:Switched
    • Easy PDU Metered Zero U 11 kW:Metered
  • Type
    • Easy PDU Switched 1U 16A:Single-phase
    • Easy PDU Metered Zero U 11 kW:Three-phase
  • Rack capacity
    • Easy PDU Switched 1U 16A:1U
    • Easy PDU Metered Zero U 11 kW:0U
  • AC outlets quantity
    • Easy PDU Switched 1U 16A:8 AC outlet(s)
    • Easy PDU Metered Zero U 11 kW:21 AC outlet(s)
  • Power plug
    • Easy PDU Switched 1U 16A:C20 coupler
    • Easy PDU Metered Zero U 11 kW:C13 coupler
  • AC outlet types
    • Easy PDU Switched 1U 16A:C13 coupler
    • Easy PDU Metered Zero U 11 kW:C13 coupler, C19 coupler
  • Nominal input voltage
    • Easy PDU Switched 1U 16A:230 V
    • Easy PDU Metered Zero U 11 kW:400 V
  • Output voltage
    • Easy PDU Switched 1U 16A:208 V
    • Easy PDU Metered Zero U 11 kW:230 V

Side by side

Differences highlightedShow differences only (off)
Comparison of EPDU2016S, EPDU2216M
30 specifications
Design3 differ
PDU typesDiffersSwitchedMetered
TypeDiffersSingle-phaseThree-phase
Rack capacityDiffers1U0U
MountingVerticalVertical
Product colourBlackBlack
Ports & interfaces3 differ
AC outlets quantityDiffers8 AC outlet(s)21 AC outlet(s)
Power plugDiffersC20 couplerC13 coupler
AC outlet typesDiffersC13 couplerC13 coupler, C19 coupler
Power4 differ
Nominal input voltageDiffers230 V400 V
AC input frequency50/60 Hz50/60 Hz
Maximum current16 A16 A
Nominal output voltageKnown for oneUnknown — not stated by the source230 V
Output voltageDiffers208 V230 V
Load capacityDiffers3680 VA11040 VA
Number of phasesDiffers13
Certificatesidentical
Compliance certificatesCE, UKCACE, UKCA
Operational conditionsidentical
Operating temperature (T-T)-5 - 50 °C-5 - 50 °C
Storage temperature (T-T)-25 - 65 °C-25 - 65 °C
Operating relative humidity (H-H)5 - 95%5 - 95%
Storage relative humidity (H-H)5 - 95%5 - 95%
Operating altitude0 - 3000 m0 - 3000 m
Weight & dimensions4 differ
WidthDiffers482 mm56 mm
DepthDiffers150 mm56 mm
HeightDiffers44 mm1650 mm
WeightDiffers2.45 kg3.3 kg
Packaging data4 differ
Package weightDiffers3.8 kg4.5 kg
Package widthDiffers260 mm170 mm
Package depthDiffers570 mm1810 mm
Package heightDiffers680 mm1260 mm
Logistics data1 differ
Total carbon footprint (kg of CO2e)Differs8141239

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.