Product comparison · 2 power distribution units (pdus)

APC Easy PDU Metered 1U 16A vs APC NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets

Add a product
  • 25specifications compared
  • 21differ
  • 4identical
  • 7known for one product only

Key differences

The APC NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets has 1 U more rack capacity than the APC Easy PDU Metered 1U 16A (2U vs 1U). The APC Easy PDU Metered 1U 16A has 22 V more nominal input voltage than the APC NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets (230 V vs 208 V). The APC NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets has 44 A more maximum current than the APC Easy PDU Metered 1U 16A (60 A vs 16 A). PDU types: Metered on the APC Easy PDU Metered 1U 16A, Switched on the APC NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets. Type: Single-phase on the APC Easy PDU Metered 1U 16A, Three-phase on the APC NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets.

  • PDU types
    • Easy PDU Metered 1U 16A:Metered
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:Switched
  • Type
    • Easy PDU Metered 1U 16A:Single-phase
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:Three-phase
  • Rack capacity
    • Easy PDU Metered 1U 16A:1U
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:2U
  • Mounting
    • Easy PDU Metered 1U 16A:Vertical
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:Horizontal
  • AC outlets quantity
    • Easy PDU Metered 1U 16A:8 AC outlet(s)
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:18 AC outlet(s)
  • Power plug
    • Easy PDU Metered 1U 16A:C13 coupler
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:IEC309
  • Nominal input voltage
    • Easy PDU Metered 1U 16A:230 V
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:208 V
  • Maximum current
    • Easy PDU Metered 1U 16A:16 A
    • NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:60 A

Side by side

Differences highlightedShow differences only (off)
Comparison of EPDU2016M, NetShelter Rack PDU Advanced Switched, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets
32 specifications
Design4 differ
PDU typesDiffersMeteredSwitched
TypeDiffersSingle-phaseThree-phase
Rack capacityDiffers1U2U
MountingDiffersVerticalHorizontal
Product colourBlackBlack
Ports & interfaces3 differ
AC outlets quantityDiffers8 AC outlet(s)18 AC outlet(s)
Power plugDiffersC13 couplerIEC309
AC outlet typesDiffersC13 couplerC13 coupler, C15 coupler, C19 coupler, C21 coupler
Power3 differ
Nominal input voltageDiffers230 V208 V
AC input frequency50/60 Hz50/60 Hz
Maximum currentDiffers16 A60 A
Nominal output voltageKnown for one208 VUnknown — not stated by the source
Output voltage208 V208 V
Load capacityDiffers3680 VA17300 VA
Number of phasesKnown for one1Unknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneCE, UKCAUnknown — not stated by the source
Operational conditions3 differ
Operating temperature (T-T)Differs-5 - 50 °C-5 - 60 °C
Storage temperature (T-T)Differs-25 - 65 °C-20 - 60 °C
Operating relative humidity (H-H)Differs5 - 95%5 - 90%
Storage relative humidity (H-H)5 - 95%5 - 95%
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for oneUnknown — not stated by the source0 - 15240 m
Weight & dimensions4 differ
WidthDiffers482 mm443 mm
DepthDiffers100 mm750 mm
HeightDiffers44 mm85 mm
WeightDiffers1.7 kg15.7 kg
Packaging data4 differ
Package weightDiffers3 kg22.2 kg
Package widthDiffers210 mm600 mm
Package depthDiffers570 mm165 mm
Package heightDiffers680 mm940 mm
Logistics dataidentical
Total carbon footprint (kg of CO2e)Known for one649Unknown — not stated by the source
Featuresidentical
International Protection (IP) codeKnown for oneUnknown — not stated by the sourceIP44

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons

All power distribution units (pdus) comparisons