Product comparison · 2 power distribution units (pdus)

APC Easy PDU Metered 1U 16A vs APC NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet

Add a product
  • 22specifications compared
  • 19differ
  • 3identical
  • 23known for one product only

Key differences

The APC Easy PDU Metered 1U 16A has 1 U more rack capacity than the APC NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet (1U vs 0U). The APC NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet has 44 A more maximum current than the APC Easy PDU Metered 1U 16A (60 A vs 16 A). The APC NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet has 192 V more nominal output voltage than the APC Easy PDU Metered 1U 16A (400 V vs 208 V). Type: Single-phase on the APC Easy PDU Metered 1U 16A, Three-phase on the APC NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet. AC outlets quantity: 8 AC outlet(s) on the APC Easy PDU Metered 1U 16A, 42 AC outlet(s) on the APC NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet.

  • Type
    • Easy PDU Metered 1U 16A:Single-phase
    • NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:Three-phase
  • Rack capacity
    • Easy PDU Metered 1U 16A:1U
    • NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:0U
  • AC outlets quantity
    • Easy PDU Metered 1U 16A:8 AC outlet(s)
    • NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:42 AC outlet(s)
  • Nominal input voltage
    • Easy PDU Metered 1U 16A:230 V
    • NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:415 3 phases; 400 3 phases
  • Maximum current
    • Easy PDU Metered 1U 16A:16 A
    • NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:60 A
  • Nominal output voltage
    • Easy PDU Metered 1U 16A:208 V
    • NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:400 V
  • Output voltage
    • Easy PDU Metered 1U 16A:208 V
    • NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:240 V
  • Load capacity
    • Easy PDU Metered 1U 16A:3680 VA
    • NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:34600 VA

Side by side

Differences highlightedShow differences only (on)
Comparison of EPDU2016M, NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet
45 specifications
Design2 differ
TypeDiffersSingle-phaseThree-phase
Rack capacityDiffers1U0U
MountingKnown for oneVerticalUnknown — not stated by the source
Ports & interfaces2 differ
AC outlets quantityDiffers8 AC outlet(s)42 AC outlet(s)
AC outlet typesDiffersC13 couplerC13 coupler, C15 coupler, C19 coupler, C21 coupler
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source5
USB ports quantityKnown for oneUnknown — not stated by the source1
Input connection typeKnown for oneUnknown — not stated by the sourceIEC 60309 30 A 3P + N + PE
Power plugKnown for oneC13 couplerUnknown — not stated by the source
Featuresidentical
Cable lengthKnown for oneUnknown — not stated by the source3 m
Management featuresidentical
Management platformKnown for oneUnknown — not stated by the sourceNMC3
Power6 differ
Nominal input voltageDiffers230 V415 3 phases; 400 3 phases
Maximum currentDiffers16 A60 A
Nominal output voltageDiffers208 V400 V
Output voltageDiffers208 V240 V
Load capacityDiffers3680 VA34600 VA
Number of phasesDiffers13
Battery replacement accessibilityKnown for oneUnknown — not stated by the sourceNon-removable
Certificates1 differ
Compliance certificatesDiffersCE, UKCARoHS, REACH, WEEE
Waste Electrical and Electronic Equipment (WEEE) complianceKnown for oneUnknown — not stated by the sourceYes
CertificationKnown for oneUnknown — not stated by the sourceUKCA
Weight & dimensions4 differ
WidthDiffers482 mm56 mm
DepthDiffers100 mm75 mm
HeightDiffers44 mm1780 mm
WeightDiffers1.7 kg9.6 kg
Packaging data4 differ
Package weightDiffers3 kg17 kg
Package widthDiffers210 mm132 mm
Package depthDiffers570 mm262 mm
Package heightDiffers680 mm2110 mm
Technical detailsidentical
Preferred mounting positionKnown for oneUnknown — not stated by the sourceno preference
Removable batteryKnown for oneUnknown — not stated by the sourceNo
Packaging without single use plasticKnown for oneUnknown — not stated by the sourceNo
SCIP numberKnown for oneUnknown — not stated by the source31346aed-552c-4a16-81d9-e683a383b6da
Sustainable packagingKnown for oneUnknown — not stated by the sourceNo
Take-back systemKnown for oneUnknown — not stated by the sourceNo
Logistics dataidentical
Customs product code (TARIC)Known for oneUnknown — not stated by the source8537109899
Total carbon footprint (kg of CO2e)Known for one649Unknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)Known for one-5 - 50 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-25 - 65 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.