Product comparison · 2 power distribution units (pdus)

APC Easy PDU Metered 1U 16A vs APC Easy PDU Switched Zero U 32A

Add a product
  • 30specifications compared
  • 17differ
  • 13identical
  • 0known for one product only

Key differences

The APC Easy PDU Metered 1U 16A has 1 U more rack capacity than the APC Easy PDU Switched Zero U 32A (1U vs 0U). The APC Easy PDU Switched Zero U 32A has 16 A more maximum current than the APC Easy PDU Metered 1U 16A (32 A vs 16 A). The APC Easy PDU Switched Zero U 32A has 22 V more nominal output voltage than the APC Easy PDU Metered 1U 16A (230 V vs 208 V). PDU types: Metered on the APC Easy PDU Metered 1U 16A, Switched on the APC Easy PDU Switched Zero U 32A. AC outlets quantity: 8 AC outlet(s) on the APC Easy PDU Metered 1U 16A, 17 AC outlet(s) on the APC Easy PDU Switched Zero U 32A.

  • PDU types
    • Easy PDU Metered 1U 16A:Metered
    • Easy PDU Switched Zero U 32A:Switched
  • Rack capacity
    • Easy PDU Metered 1U 16A:1U
    • Easy PDU Switched Zero U 32A:0U
  • AC outlets quantity
    • Easy PDU Metered 1U 16A:8 AC outlet(s)
    • Easy PDU Switched Zero U 32A:17 AC outlet(s)
  • Power plug
    • Easy PDU Metered 1U 16A:C13 coupler
    • Easy PDU Switched Zero U 32A:IEC 60309
  • Maximum current
    • Easy PDU Metered 1U 16A:16 A
    • Easy PDU Switched Zero U 32A:32 A
  • Nominal output voltage
    • Easy PDU Metered 1U 16A:208 V
    • Easy PDU Switched Zero U 32A:230 V
  • Output voltage
    • Easy PDU Metered 1U 16A:208 V
    • Easy PDU Switched Zero U 32A:230 V
  • Load capacity
    • Easy PDU Metered 1U 16A:3680 VA
    • Easy PDU Switched Zero U 32A:7360 VA

Side by side

Differences highlightedShow differences only (off)
Comparison of EPDU2016M, EPDU2132S
30 specifications
Design2 differ
PDU typesDiffersMeteredSwitched
TypeSingle-phaseSingle-phase
Rack capacityDiffers1U0U
MountingVerticalVertical
Product colourBlackBlack
Ports & interfaces2 differ
AC outlets quantityDiffers8 AC outlet(s)17 AC outlet(s)
Power plugDiffersC13 couplerIEC 60309
AC outlet typesC13 couplerC13 coupler
Power4 differ
Nominal input voltage230 V230 V
AC input frequency50/60 Hz50/60 Hz
Maximum currentDiffers16 A32 A
Nominal output voltageDiffers208 V230 V
Output voltageDiffers208 V230 V
Load capacityDiffers3680 VA7360 VA
Number of phases11
Certificatesidentical
Compliance certificatesCE, UKCACE, UKCA
Operational conditionsidentical
Operating temperature (T-T)-5 - 50 °C-5 - 50 °C
Storage temperature (T-T)-25 - 65 °C-25 - 65 °C
Operating relative humidity (H-H)5 - 95%5 - 95%
Storage relative humidity (H-H)5 - 95%5 - 95%
Operating altitude0 - 3000 m0 - 3000 m
Weight & dimensions4 differ
WidthDiffers482 mm56 mm
DepthDiffers100 mm62 mm
HeightDiffers44 mm1650 mm
WeightDiffers1.7 kg6.65 kg
Packaging data4 differ
Package weightDiffers3 kg8.15 kg
Package widthDiffers210 mm170 mm
Package depthDiffers570 mm1810 mm
Package heightDiffers680 mm1260 mm
Logistics data1 differ
Total carbon footprint (kg of CO2e)Differs6491310

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons

All power distribution units (pdus) comparisons