Product comparison · 2 power distribution units (pdus)

APC Easy Rack vs APC Easy PDU Metered Zero U 22 kW

Add a product
  • 23specifications compared
  • 18differ
  • 5identical
  • 9known for one product only

Key differences

The APC Easy Rack has 1 U more rack capacity than the APC Easy PDU Metered Zero U 22 kW (1U vs 0U). The APC Easy PDU Metered Zero U 22 kW has 16 A more maximum current than the APC Easy Rack (32 A vs 16 A). The APC Easy PDU Metered Zero U 22 kW has 11.5 mm more width than the APC Easy Rack (56 mm vs 44.5 mm). PDU types: Basic on the APC Easy Rack, Metered on the APC Easy PDU Metered Zero U 22 kW. Type: Single-phase on the APC Easy Rack, Three-phase on the APC Easy PDU Metered Zero U 22 kW.

  • PDU types
    • Easy Rack:Basic
    • Easy PDU Metered Zero U 22 kW:Metered
  • Type
    • Easy Rack:Single-phase
    • Easy PDU Metered Zero U 22 kW:Three-phase
  • Rack capacity
    • Easy Rack:1U
    • Easy PDU Metered Zero U 22 kW:0U
  • Mounting
    • Easy Rack:Horizontal
    • Easy PDU Metered Zero U 22 kW:Vertical
  • AC outlets quantity
    • Easy Rack:8 AC outlet(s)
    • Easy PDU Metered Zero U 22 kW:24 AC outlet(s)
  • Power plug
    • Easy Rack:C20 coupler
    • Easy PDU Metered Zero U 22 kW:C13 coupler
  • AC outlet types
    • Easy Rack:C13 coupler
    • Easy PDU Metered Zero U 22 kW:C13 coupler, C19 coupler
  • Nominal input voltage
    • Easy Rack:200 - 240 V
    • Easy PDU Metered Zero U 22 kW:400 V

Side by side

Differences highlightedShow differences only (on)
Comparison of Easy Rack, EPDU2232M
32 specifications
Design4 differ
PDU typesDiffersBasicMetered
TypeDiffersSingle-phaseThree-phase
Rack capacityDiffers1U0U
MountingDiffersHorizontalVertical
Ports & interfaces3 differ
AC outlets quantityDiffers8 AC outlet(s)24 AC outlet(s)
Power plugDiffersC20 couplerC13 coupler
AC outlet typesDiffersC13 couplerC13 coupler, C19 coupler
Power2 differ
Nominal input voltageDiffers200 - 240 V400 V
Maximum currentDiffers16 A32 A
Nominal output voltageKnown for oneUnknown — not stated by the source230 V
Load capacityKnown for oneUnknown — not stated by the source22080 VA
Number of phasesKnown for oneUnknown — not stated by the source3
Maximum powerKnown for one3700 WUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneUnknown — not stated by the sourceCE, UKCA
CertificationKnown for oneCEUnknown — not stated by the source
Operational conditions2 differ
Operating temperature (T-T)Differs-5 - 60 °C-5 - 50 °C
Storage temperature (T-T)Differs-25 - 60 °C-25 - 65 °C
Storage relative humidity (H-H)Known for oneUnknown — not stated by the source5 - 95%
Operating altitudeKnown for oneUnknown — not stated by the source0 - 3000 m
Weight & dimensions4 differ
WidthDiffers44.5 mm56 mm
DepthDiffers482 mm56 mm
HeightDiffers44.5 mm1650 mm
WeightDiffers550 g4.85 kg
Packaging data3 differ
Package weightDiffers1.35 kg6.05 kg
Package depthDiffers570 mm1810 mm
Package heightDiffers73 mm1260 mm
Logistics dataidentical
Total carbon footprint (kg of CO2e)Known for oneUnknown — not stated by the source1655

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons

All power distribution units (pdus) comparisons