Product comparison · 2 power distribution units (pdus)

APC APDU11452SW power distribution unit (PDU) 42 AC outlet(s) 0U Blue, Black vs APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets

Add a product
  • 17specifications compared
  • 16differ
  • 1identical
  • 25known for one product only

Key differences

The APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets has 40 A more maximum current than the APC APDU11452SW power distribution unit (PDU) 42 AC outlet(s) 0U Blue, Black (100 A vs 60 A). The APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets has 51,700 VA more load capacity than the APC APDU11452SW power distribution unit (PDU) 42 AC outlet(s) 0U Blue, Black (69000 VA vs 17300 VA). The APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets has 29 mm more width than the APC APDU11452SW power distribution unit (PDU) 42 AC outlet(s) 0U Blue, Black (85 mm vs 56 mm). PDU types: Switched on the APC APDU11452SW power distribution unit (PDU) 42 AC outlet(s) 0U Blue, Black, Switched, Metered-by-outlet on the APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets. Product colour: Blue, Black on the APC APDU11452SW power distribution unit (PDU) 42 AC outlet(s) 0U Blue, Black, Black on the APC NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets.

  • PDU types
    • APDU11452SW power distribution unit (PDU) 42 AC outlet(s) 0U Blue, Black:Switched
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:Switched, Metered-by-outlet
  • Product colour
    • APDU11452SW power distribution unit (PDU) 42 AC outlet(s) 0U Blue, Black:Blue, Black
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:Black
  • AC outlets quantity
    • APDU11452SW power distribution unit (PDU) 42 AC outlet(s) 0U Blue, Black:42 AC outlet(s)
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:18 AC outlet(s)
  • Power plug
    • APDU11452SW power distribution unit (PDU) 42 AC outlet(s) 0U Blue, Black:IEC 60309
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:IEC309
  • Maximum current
    • APDU11452SW power distribution unit (PDU) 42 AC outlet(s) 0U Blue, Black:60 A
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:100 A
  • Output voltage
    • APDU11452SW power distribution unit (PDU) 42 AC outlet(s) 0U Blue, Black:208 V
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:415 V AC 3 phases
  • Load capacity
    • APDU11452SW power distribution unit (PDU) 42 AC outlet(s) 0U Blue, Black:17300 VA
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:69000 VA
  • Width
    • APDU11452SW power distribution unit (PDU) 42 AC outlet(s) 0U Blue, Black:56 mm
    • NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets:85 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of APDU11452SW, NetShelter Rack PDU Advanced Switched Metered, 0U, 3 Phase, 415V, 69.0kVA 100A, 36 Outlets
42 specifications
Design2 differ
PDU typesDiffersSwitchedSwitched, Metered-by-outlet
TypeKnown for oneUnknown — not stated by the sourceThree-phase
Rack capacity0U0U
MountingKnown for oneUnknown — not stated by the sourceVertical
Product colourDiffersBlue, BlackBlack
UpgradeableKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces3 differ
AC outlets quantityDiffers42 AC outlet(s)18 AC outlet(s)
Power plugDiffersIEC 60309IEC309
AC outlet typesDiffersC13 coupler, C19 coupler, C15 coupler, C21 couplerC13 coupler, C15 coupler, C19 coupler, C21 coupler
Input connection typeKnown for oneUnknown — not stated by the sourceIEC 309 100 A
Featuresidentical
International Protection (IP) codeKnown for oneUnknown — not stated by the sourceIP67
Cable lengthKnown for one3 mUnknown — not stated by the source
Management featuresidentical
Management platformKnown for oneUnknown — not stated by the sourceNMC3
Power3 differ
Nominal input voltageKnown for oneUnknown — not stated by the source415 3 phases
AC input frequencyKnown for oneUnknown — not stated by the source50/60 Hz
Maximum currentDiffers60 A100 A
Output voltageDiffers208 V415 V AC 3 phases
Load capacityDiffers17300 VA69000 VA
Number of phasesKnown for oneUnknown — not stated by the source3
Maximum powerKnown for one43500 WUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneUnknown — not stated by the sourceRoHS, REACH, WEEE
Waste Electrical and Electronic Equipment (WEEE) complianceKnown for oneUnknown — not stated by the sourceYes
Sustainabilityidentical
Doesn't containKnown for oneUnknown — not stated by the sourceSilicone
Operational conditionsidentical
Operating temperature (T-T)Known for oneUnknown — not stated by the source-5 - 60 °C
Storage temperature (T-T)Known for oneUnknown — not stated by the source-20 - 60 °C
Operating relative humidity (H-H)Known for oneUnknown — not stated by the source5 - 90%
Storage relative humidity (H-H)Known for oneUnknown — not stated by the source5 - 95%
Non-operating altitudeKnown for oneUnknown — not stated by the source0 - 15240 m
Weight & dimensions4 differ
WidthDiffers56 mm85 mm
DepthDiffers75 mm85 mm
HeightDiffers1826 mm1980 mm
WeightDiffers11.1 kg20.7 kg
Packaging data4 differ
Package weightDiffers14.1 kg26.5 kg
Package widthDiffers132 mm350 mm
Package depthDiffers2620 mm165 mm
Package heightDiffers1980 mm2320 mm
Technical detailsidentical
Packaging recycled materialsKnown for oneUnknown — not stated by the sourceRecycled cardboard
Preferred mounting positionKnown for oneUnknown — not stated by the sourceno preference
Packaging without single use plasticKnown for oneUnknown — not stated by the sourceYes
SCIP numberKnown for oneUnknown — not stated by the source7547f066-9302-46d9-96e9-461928dd6901
Sustainable packagingKnown for oneUnknown — not stated by the sourceNo
Take-back systemKnown for oneUnknown — not stated by the sourceNo