Product comparison · 2 power distribution units (pdus)

APC APDU11452MO power distribution unit (PDU) 42 AC outlet(s) 0U Black vs Vertiv PowerIT VP4G31A2 power distribution unit (PDU) 36 AC outlet(s) 0U Black

Add a product
  • 16specifications compared
  • 10differ
  • 6identical
  • 21known for one product only

Key differences

The APC APDU11452MO power distribution unit (PDU) 42 AC outlet(s) 0U Black has 28 A more maximum current than the Vertiv PowerIT VP4G31A2 power distribution unit (PDU) 36 AC outlet(s) 0U Black (60 A vs 32 A). The APC APDU11452MO power distribution unit (PDU) 42 AC outlet(s) 0U Black has 17,070 VA more load capacity than the Vertiv PowerIT VP4G31A2 power distribution unit (PDU) 36 AC outlet(s) 0U Black (17300 VA vs 230 VA). The APC APDU11452MO power distribution unit (PDU) 42 AC outlet(s) 0U Black has 5 mm more width than the Vertiv PowerIT VP4G31A2 power distribution unit (PDU) 36 AC outlet(s) 0U Black (56 mm vs 51 mm). PDU types: Metered on the APC APDU11452MO power distribution unit (PDU) 42 AC outlet(s) 0U Black, Switched on the Vertiv PowerIT VP4G31A2 power distribution unit (PDU) 36 AC outlet(s) 0U Black. AC outlets quantity: 42 AC outlet(s) on the APC APDU11452MO power distribution unit (PDU) 42 AC outlet(s) 0U Black, 36 AC outlet(s) on the Vertiv PowerIT VP4G31A2 power distribution unit (PDU) 36 AC outlet(s) 0U Black.

  • PDU types
    • APDU11452MO power distribution unit (PDU) 42 AC outlet(s) 0U Black:Metered
    • PowerIT VP4G31A2 power distribution unit (PDU) 36 AC outlet(s) 0U Black:Switched
  • AC outlets quantity
    • APDU11452MO power distribution unit (PDU) 42 AC outlet(s) 0U Black:42 AC outlet(s)
    • PowerIT VP4G31A2 power distribution unit (PDU) 36 AC outlet(s) 0U Black:36 AC outlet(s)
  • Nominal input voltage
    • APDU11452MO power distribution unit (PDU) 42 AC outlet(s) 0U Black:200 - 240 V
    • PowerIT VP4G31A2 power distribution unit (PDU) 36 AC outlet(s) 0U Black:200-240/346-415 V
  • Maximum current
    • APDU11452MO power distribution unit (PDU) 42 AC outlet(s) 0U Black:60 A
    • PowerIT VP4G31A2 power distribution unit (PDU) 36 AC outlet(s) 0U Black:32 A
  • Load capacity
    • APDU11452MO power distribution unit (PDU) 42 AC outlet(s) 0U Black:17300 VA
    • PowerIT VP4G31A2 power distribution unit (PDU) 36 AC outlet(s) 0U Black:230 VA
  • Operating temperature (T-T)
    • APDU11452MO power distribution unit (PDU) 42 AC outlet(s) 0U Black:-5 - 60 °F
    • PowerIT VP4G31A2 power distribution unit (PDU) 36 AC outlet(s) 0U Black:0 - 60 °C
  • Width
    • APDU11452MO power distribution unit (PDU) 42 AC outlet(s) 0U Black:56 mm
    • PowerIT VP4G31A2 power distribution unit (PDU) 36 AC outlet(s) 0U Black:51 mm
  • Depth
    • APDU11452MO power distribution unit (PDU) 42 AC outlet(s) 0U Black:75 mm
    • PowerIT VP4G31A2 power distribution unit (PDU) 36 AC outlet(s) 0U Black:66 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of APDU11452MO, VP4G31A2
37 specifications
Design1 differ
PDU typesDiffersMeteredSwitched
TypeKnown for oneUnknown — not stated by the sourceThree-phase
Rack capacity0U0U
MountingVerticalVertical
Product colourBlackBlack
DisplayKnown for oneUnknown — not stated by the sourceLCD
Ports & interfaces1 differ
AC outlets quantityDiffers42 AC outlet(s)36 AC outlet(s)
Power plugKnown for oneUnknown — not stated by the sourceIEC 60309
AC outlet typesC13 coupler, C19 couplerC13 coupler, C19 coupler
Serial ports quantityKnown for oneUnknown — not stated by the source1
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source1
USB ports quantityKnown for oneUnknown — not stated by the source1
Featuresidentical
Reset buttonKnown for oneUnknown — not stated by the sourceYes
Cable length3 m3 m
Management featuresidentical
MonitoringKnown for oneUnknown — not stated by the sourceCurrent, Power, Voltage
Supported network protocolsKnown for oneUnknown — not stated by the sourceDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+, Modbus TCP
Power3 differ
Nominal input voltageDiffers200 - 240 V200-240/346-415 V
AC input frequency50/60 Hz50/60 Hz
Maximum currentDiffers60 A32 A
Load capacityDiffers17300 VA230 VA
Power protection featuresKnown for oneUnknown — not stated by the sourceOver current
Nominal output voltageKnown for one208 VUnknown — not stated by the source
Output voltageKnown for one208 VUnknown — not stated by the source
Maximum powerKnown for one43500 WUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneUnknown — not stated by the sourceRoHS, UKCA, CE
Operational conditions1 differ
Operating temperature (T-T)Differs-5 - 60 °F0 - 60 °C
Operating temperature (charge) (T-T)Known for one-25 - 65 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Weight & dimensions3 differ
WidthDiffers56 mm51 mm
DepthDiffers75 mm66 mm
HeightDiffers1780 mm1829 mm
WeightKnown for one11.1 kgUnknown — not stated by the source
Packaging data1 differ
Package weightDiffers14.1 kg9.98 kg
Package widthKnown for one132 mmUnknown — not stated by the source
Package depthKnown for one262 mmUnknown — not stated by the source
Package heightKnown for one1980 mmUnknown — not stated by the source
Logistics dataidentical
Warranty periodKnown for oneUnknown — not stated by the source5 year(s)

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.