Product comparison · 2 power distribution units (pdus)

APC APDU11452MO power distribution unit (PDU) 42 AC outlet(s) 0U Black vs APC NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets

Add a product
  • 21specifications compared
  • 17differ
  • 4identical
  • 24known for one product only

Key differences

The APC NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets has 2 U more rack capacity than the APC APDU11452MO power distribution unit (PDU) 42 AC outlet(s) 0U Black (2U vs 0U). The APC NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets has 24,100 VA more load capacity than the APC APDU11452MO power distribution unit (PDU) 42 AC outlet(s) 0U Black (41400 VA vs 17300 VA). The APC NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets has 387 mm more width than the APC APDU11452MO power distribution unit (PDU) 42 AC outlet(s) 0U Black (443 mm vs 56 mm). Mounting: Vertical on the APC APDU11452MO power distribution unit (PDU) 42 AC outlet(s) 0U Black, Horizontal on the APC NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets. AC outlets quantity: 42 AC outlet(s) on the APC APDU11452MO power distribution unit (PDU) 42 AC outlet(s) 0U Black, 18 AC outlet(s) on the APC NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets.

  • Rack capacity
    • APDU11452MO power distribution unit (PDU) 42 AC outlet(s) 0U Black:0U
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:2U
  • Mounting
    • APDU11452MO power distribution unit (PDU) 42 AC outlet(s) 0U Black:Vertical
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:Horizontal
  • AC outlets quantity
    • APDU11452MO power distribution unit (PDU) 42 AC outlet(s) 0U Black:42 AC outlet(s)
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:18 AC outlet(s)
  • Nominal input voltage
    • APDU11452MO power distribution unit (PDU) 42 AC outlet(s) 0U Black:200 - 240 V
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:415 3 phases
  • Output voltage
    • APDU11452MO power distribution unit (PDU) 42 AC outlet(s) 0U Black:208 V
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:415 V AC 3 phases
  • Load capacity
    • APDU11452MO power distribution unit (PDU) 42 AC outlet(s) 0U Black:17300 VA
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:41400 VA
  • Operating temperature (T-T)
    • APDU11452MO power distribution unit (PDU) 42 AC outlet(s) 0U Black:-5 - 60 °F
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:-5 - 60 °C
  • Operating relative humidity (H-H)
    • APDU11452MO power distribution unit (PDU) 42 AC outlet(s) 0U Black:5 - 95%
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets:5 - 90%

Side by side

Differences highlightedShow differences only (off)
Comparison of APDU11452MO, NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 415V, 41.4kVA 60A, 18 Outlets
45 specifications
Design2 differ
PDU typesMeteredMetered
TypeKnown for oneUnknown — not stated by the sourceThree-phase
Rack capacityDiffers0U2U
MountingDiffersVerticalHorizontal
Product colourBlackBlack
UpgradeableKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces2 differ
AC outlets quantityDiffers42 AC outlet(s)18 AC outlet(s)
Power plugKnown for oneUnknown — not stated by the sourceIEC309
AC outlet typesDiffersC13 coupler, C19 couplerC13 coupler, C15 coupler, C19 coupler, C21 coupler
Input connection typeKnown for oneUnknown — not stated by the sourceIEC 309 60 A
Featuresidentical
International Protection (IP) codeKnown for oneUnknown — not stated by the sourceIP44
Cable lengthKnown for one3 mUnknown — not stated by the source
Management featuresidentical
Management platformKnown for oneUnknown — not stated by the sourceNMC3
Power3 differ
Nominal input voltageDiffers200 - 240 V415 3 phases
AC input frequency50/60 Hz50/60 Hz
Maximum current60 A60 A
Output voltageDiffers208 V415 V AC 3 phases
Load capacityDiffers17300 VA41400 VA
Number of phasesKnown for oneUnknown — not stated by the source3
Nominal output voltageKnown for one208 VUnknown — not stated by the source
Maximum powerKnown for one43500 WUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneUnknown — not stated by the sourceRoHS, REACH, WEEE
Waste Electrical and Electronic Equipment (WEEE) complianceKnown for oneUnknown — not stated by the sourceYes
Sustainabilityidentical
Doesn't containKnown for oneUnknown — not stated by the sourceSilicone
Operational conditions2 differ
Operating temperature (T-T)Differs-5 - 60 °F-5 - 60 °C
Storage temperature (T-T)Known for oneUnknown — not stated by the source-20 - 60 °C
Operating relative humidity (H-H)Differs5 - 95%5 - 90%
Storage relative humidity (H-H)Known for oneUnknown — not stated by the source5 - 95%
Non-operating altitudeKnown for oneUnknown — not stated by the source0 - 15240 m
Operating temperature (charge) (T-T)Known for one-25 - 65 °CUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers56 mm443 mm
DepthDiffers75 mm750 mm
HeightDiffers1780 mm85 mm
WeightDiffers11.1 kg15.7 kg
Packaging data4 differ
Package weightDiffers14.1 kg22.2 kg
Package widthDiffers132 mm600 mm
Package depthDiffers262 mm165 mm
Package heightDiffers1980 mm940 mm
Technical detailsidentical
Packaging recycled materialsKnown for oneUnknown — not stated by the sourceRecycled cardboard
Preferred mounting positionKnown for oneUnknown — not stated by the sourceno preference
Packaging without single use plasticKnown for oneUnknown — not stated by the sourceYes
SCIP numberKnown for oneUnknown — not stated by the source7547f066-9302-46d9-96e9-461928dd6901
Sustainable packagingKnown for oneUnknown — not stated by the sourceNo
Take-back systemKnown for oneUnknown — not stated by the sourceNo
Logistics dataidentical
Customs product code (TARIC)Known for oneUnknown — not stated by the source8537109899