Product comparison · 2 power distribution units (pdus)

APC APDU11451ME power distribution unit (PDU) 42 AC outlet(s) 0U Black vs Vertiv Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black

Add a product
  • 16specifications compared
  • 11differ
  • 5identical
  • 19known for one product only

Key differences

The Vertiv Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black has 0.05 m more cable length than the APC APDU11451ME power distribution unit (PDU) 42 AC outlet(s) 0U Black (3.05 m vs 3 m). The Vertiv Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black has 50 A more maximum current than the APC APDU11451ME power distribution unit (PDU) 42 AC outlet(s) 0U Black (100 A vs 50 A). The APC APDU11451ME power distribution unit (PDU) 42 AC outlet(s) 0U Black has 14,192 VA more load capacity than the Vertiv Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black (14400 VA vs 208 VA). PDU types: Metered on the APC APDU11451ME power distribution unit (PDU) 42 AC outlet(s) 0U Black, Monitored on the Vertiv Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black. AC outlets quantity: 42 AC outlet(s) on the APC APDU11451ME power distribution unit (PDU) 42 AC outlet(s) 0U Black, 24 AC outlet(s) on the Vertiv Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black.

  • PDU types
    • APDU11451ME power distribution unit (PDU) 42 AC outlet(s) 0U Black:Metered
    • Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:Monitored
  • AC outlets quantity
    • APDU11451ME power distribution unit (PDU) 42 AC outlet(s) 0U Black:42 AC outlet(s)
    • Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:24 AC outlet(s)
  • Cable length
    • APDU11451ME power distribution unit (PDU) 42 AC outlet(s) 0U Black:3 m
    • Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:3.05 m
  • Nominal input voltage
    • APDU11451ME power distribution unit (PDU) 42 AC outlet(s) 0U Black:200 - 240 V
    • Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:208 V
  • Maximum current
    • APDU11451ME power distribution unit (PDU) 42 AC outlet(s) 0U Black:50 A
    • Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:100 A
  • Load capacity
    • APDU11451ME power distribution unit (PDU) 42 AC outlet(s) 0U Black:14400 VA
    • Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:208 VA
  • Operating temperature (T-T)
    • APDU11451ME power distribution unit (PDU) 42 AC outlet(s) 0U Black:-5 - 60 °F
    • Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:10 - 45 °C
  • Width
    • APDU11451ME power distribution unit (PDU) 42 AC outlet(s) 0U Black:56 mm
    • Geist MN05MGW1-24CF18-8PS15D0A10-S power distribution unit (PDU) 24 AC outlet(s) 0U Black:97 mm

Side by side

Differences highlightedShow differences only (on)
Comparison of APDU11451ME, MN05MGW1-24CF18-8PS15D0A10-S
35 specifications
Design1 differ
PDU typesDiffersMeteredMonitored
TypeKnown for oneUnknown — not stated by the sourceThree-phase
DisplayKnown for oneUnknown — not stated by the sourceLCD
Ports & interfaces1 differ
AC outlets quantityDiffers42 AC outlet(s)24 AC outlet(s)
Power plugKnown for oneUnknown — not stated by the sourceIEC 60309
Serial ports quantityKnown for oneUnknown — not stated by the source1
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source1
USB ports quantityKnown for oneUnknown — not stated by the source1
Features1 differ
Cable lengthDiffers3 m3.05 m
Reset buttonKnown for oneUnknown — not stated by the sourceYes
LED indicatorsKnown for oneUnknown — not stated by the sourceYes
Power3 differ
Nominal input voltageDiffers200 - 240 V208 V
Maximum currentDiffers50 A100 A
Nominal output voltageKnown for one208 VUnknown — not stated by the source
Output voltageKnown for one208 VUnknown — not stated by the source
Load capacityDiffers14400 VA208 VA
Maximum powerKnown for one14400 WUnknown — not stated by the source
Operational conditions1 differ
Operating temperature (T-T)Differs-5 - 60 °F10 - 45 °C
Operating temperature (charge) (T-T)Known for one-25 - 65 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Non-operating altitudeKnown for one0 - 15240 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers56 mm97 mm
DepthDiffers75 mm76 mm
HeightDiffers1780 mm1683 mm
WeightDiffers10.6 kg8.6 kg
Packaging dataidentical
Package weightKnown for one13.6 kgUnknown — not stated by the source
Package widthKnown for one132 mmUnknown — not stated by the source
Package depthKnown for one262 mmUnknown — not stated by the source
Package heightKnown for one1980 mmUnknown — not stated by the source
Certificatesidentical
CertificationKnown for oneUnknown — not stated by the sourceUL & c-UL Listed 62368-1 RoHS Compliant FCC Part 15 Class A Conformance

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons