The ATEN 1U 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software has 1 U more rack capacity than the APC APDU11351SW power distribution unit (PDU) 48 AC outlet(s) 0U Black (1U vs 0U). The APC APDU11351SW power distribution unit (PDU) 48 AC outlet(s) 0U Black has 100 - 240 V more nominal input voltage than the ATEN 1U 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software (200 - 240 V vs 100 - 240 V). The APC APDU11351SW power distribution unit (PDU) 48 AC outlet(s) 0U Black has 14 A more maximum current than the ATEN 1U 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software (30 A vs 16 A). PDU types: Switched on the APC APDU11351SW power distribution unit (PDU) 48 AC outlet(s) 0U Black, Managed, Metered, Switched on the ATEN 1U 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software. Mounting: Vertical on the APC APDU11351SW power distribution unit (PDU) 48 AC outlet(s) 0U Black, Horizontal on the ATEN 1U 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software.

  • PDU types
    • APDU11351SW power distribution unit (PDU) 48 AC outlet(s) 0U Black:Switched
    • 1U 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software:Managed, Metered, Switched
  • Rack capacity
    • APDU11351SW power distribution unit (PDU) 48 AC outlet(s) 0U Black:0U
    • 1U 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software:1U
  • Mounting
    • APDU11351SW power distribution unit (PDU) 48 AC outlet(s) 0U Black:Vertical
    • 1U 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software:Horizontal
  • AC outlets quantity
    • APDU11351SW power distribution unit (PDU) 48 AC outlet(s) 0U Black:48 AC outlet(s)
    • 1U 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software:8 AC outlet(s)
  • Nominal input voltage
    • APDU11351SW power distribution unit (PDU) 48 AC outlet(s) 0U Black:200 - 240 V
    • 1U 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software:100 - 240 V
  • AC input frequency
    • APDU11351SW power distribution unit (PDU) 48 AC outlet(s) 0U Black:50/60 Hz
    • 1U 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software:50 - 60 Hz
  • Maximum current
    • APDU11351SW power distribution unit (PDU) 48 AC outlet(s) 0U Black:30 A
    • 1U 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software:16 A
  • Load capacity
    • APDU11351SW power distribution unit (PDU) 48 AC outlet(s) 0U Black:8600 VA
    • 1U 16A 8 Outlet Switched Bank Metered PDU + Free Eco PDU Manager Software:380 VA

Side by side

Differences highlightedShow differences only (on)
Comparison of APDU11351SW, PE6208G-ATB-G
39 specifications
Design3 differ
PDU typesDiffersSwitchedManaged, Metered, Switched
TypeKnown for oneUnknown — not stated by the sourceSingle-phase
Rack capacityDiffers0U1U
MountingDiffersVerticalHorizontal
Housing materialKnown for oneUnknown — not stated by the sourceMetal
DisplayKnown for oneUnknown — not stated by the sourceYes
On/off switchKnown for oneUnknown — not stated by the sourceYes
Ports & interfaces1 differ
AC outlets quantityDiffers48 AC outlet(s)8 AC outlet(s)
Power plugKnown for oneUnknown — not stated by the sourceC20 coupler
Management featuresidentical
MonitoringKnown for oneUnknown — not stated by the sourceCurrent
Outlet controlKnown for oneUnknown — not stated by the sourceTurn off, Turn on
Power5 differ
Nominal input voltageDiffers200 - 240 V100 - 240 V
AC input frequencyDiffers50/60 Hz50 - 60 Hz
Maximum currentDiffers30 A16 A
Load capacityDiffers8600 VA380 VA
Maximum total current draw per phaseKnown for oneUnknown — not stated by the source16 A
Maximum powerDiffers8600 W100 W
Nominal output voltageKnown for one208 VUnknown — not stated by the source
Output voltageKnown for one208 VUnknown — not stated by the source
Operational conditions2 differ
Operating temperature (T-T)Differs-5 - 60 °F0 - 50 °C
Storage temperature (T-T)Known for oneUnknown — not stated by the source-20 - 60 °C
Operating relative humidity (H-H)Differs5 - 95%0 - 80%
Operating temperature (charge) (T-T)Known for one-25 - 65 °CUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers56 mm220.4 mm
DepthDiffers75 mm432.4 mm
HeightDiffers1780 mm44 mm
WeightDiffers9.4 kg2.79 kg
Packaging data2 differ
Package depthDiffers208 mm499 mm
Package heightDiffers1980 mm324 mm
Package weightKnown for one12.4 kgUnknown — not stated by the source
Logistics dataidentical
Master (outer) case net weightKnown for oneUnknown — not stated by the source9.87 kg
Master (outer) case widthKnown for oneUnknown — not stated by the source388 mm
Master (outer) case lengthKnown for oneUnknown — not stated by the source519 mm
Master (outer) case heightKnown for oneUnknown — not stated by the source348 mm
Master (outer) case gross weightKnown for oneUnknown — not stated by the source13 kg

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.