Product comparison · 2 power distribution units (pdus)

APC APDU11351SW power distribution unit (PDU) 48 AC outlet(s) 0U Black vs APC Easy PDU Metered Zero U 22 kW

Add a product
  • 22specifications compared
  • 15differ
  • 7identical
  • 11known for one product only

Key differences

The APC Easy PDU Metered Zero U 22 kW has 2 A more maximum current than the APC APDU11351SW power distribution unit (PDU) 48 AC outlet(s) 0U Black (32 A vs 30 A). The APC Easy PDU Metered Zero U 22 kW has 22 V more nominal output voltage than the APC APDU11351SW power distribution unit (PDU) 48 AC outlet(s) 0U Black (230 V vs 208 V). The APC Easy PDU Metered Zero U 22 kW has 22 V more output voltage than the APC APDU11351SW power distribution unit (PDU) 48 AC outlet(s) 0U Black (230 V vs 208 V). PDU types: Switched on the APC APDU11351SW power distribution unit (PDU) 48 AC outlet(s) 0U Black, Metered on the APC Easy PDU Metered Zero U 22 kW. AC outlets quantity: 48 AC outlet(s) on the APC APDU11351SW power distribution unit (PDU) 48 AC outlet(s) 0U Black, 24 AC outlet(s) on the APC Easy PDU Metered Zero U 22 kW.

  • PDU types
    • APDU11351SW power distribution unit (PDU) 48 AC outlet(s) 0U Black:Switched
    • Easy PDU Metered Zero U 22 kW:Metered
  • AC outlets quantity
    • APDU11351SW power distribution unit (PDU) 48 AC outlet(s) 0U Black:48 AC outlet(s)
    • Easy PDU Metered Zero U 22 kW:24 AC outlet(s)
  • Nominal input voltage
    • APDU11351SW power distribution unit (PDU) 48 AC outlet(s) 0U Black:200 - 240 V
    • Easy PDU Metered Zero U 22 kW:400 V
  • Maximum current
    • APDU11351SW power distribution unit (PDU) 48 AC outlet(s) 0U Black:30 A
    • Easy PDU Metered Zero U 22 kW:32 A
  • Nominal output voltage
    • APDU11351SW power distribution unit (PDU) 48 AC outlet(s) 0U Black:208 V
    • Easy PDU Metered Zero U 22 kW:230 V
  • Output voltage
    • APDU11351SW power distribution unit (PDU) 48 AC outlet(s) 0U Black:208 V
    • Easy PDU Metered Zero U 22 kW:230 V
  • Load capacity
    • APDU11351SW power distribution unit (PDU) 48 AC outlet(s) 0U Black:8600 VA
    • Easy PDU Metered Zero U 22 kW:22080 VA
  • Operating temperature (T-T)
    • APDU11351SW power distribution unit (PDU) 48 AC outlet(s) 0U Black:-5 - 60 °F
    • Easy PDU Metered Zero U 22 kW:-5 - 50 °C

Side by side

Differences highlightedShow differences only (off)
Comparison of APDU11351SW, EPDU2232M
33 specifications
Design1 differ
PDU typesDiffersSwitchedMetered
TypeKnown for oneUnknown — not stated by the sourceThree-phase
Rack capacity0U0U
MountingVerticalVertical
Product colourBlackBlack
Ports & interfaces1 differ
AC outlets quantityDiffers48 AC outlet(s)24 AC outlet(s)
Power plugKnown for oneUnknown — not stated by the sourceC13 coupler
AC outlet typesC13 coupler, C19 couplerC13 coupler, C19 coupler
Power5 differ
Nominal input voltageDiffers200 - 240 V400 V
AC input frequency50/60 Hz50/60 Hz
Maximum currentDiffers30 A32 A
Nominal output voltageDiffers208 V230 V
Output voltageDiffers208 V230 V
Load capacityDiffers8600 VA22080 VA
Number of phasesKnown for oneUnknown — not stated by the source3
Maximum powerKnown for one8600 WUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneUnknown — not stated by the sourceCE, UKCA
Operational conditions1 differ
Operating temperature (T-T)Differs-5 - 60 °F-5 - 50 °C
Storage temperature (T-T)Known for oneUnknown — not stated by the source-25 - 65 °C
Operating relative humidity (H-H)5 - 95%5 - 95%
Storage relative humidity (H-H)Known for oneUnknown — not stated by the source5 - 95%
Operating altitudeKnown for oneUnknown — not stated by the source0 - 3000 m
Operating temperature (charge) (T-T)Known for one-25 - 65 °CUnknown — not stated by the source
Weight & dimensions3 differ
Width56 mm56 mm
DepthDiffers75 mm56 mm
HeightDiffers1780 mm1650 mm
WeightDiffers9.4 kg4.85 kg
Packaging data4 differ
Package weightDiffers12.4 kg6.05 kg
Package widthDiffers116 mm170 mm
Package depthDiffers208 mm1810 mm
Package heightDiffers1980 mm1260 mm
Logistics dataidentical
Total carbon footprint (kg of CO2e)Known for oneUnknown — not stated by the source1655
Featuresidentical
Cable lengthKnown for one3 mUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.