Product comparison · 2 power distribution units (pdus)

APC AP8867US power distribution unit (PDU) 30 AC outlet(s) 0U Black vs Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black

Add a product
  • 16specifications compared
  • 12differ
  • 4identical
  • 21known for one product only

Key differences

The Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black has 2 U more rack capacity than the APC AP8867US power distribution unit (PDU) 30 AC outlet(s) 0U Black (2U vs 0U). The Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black has 1.18 m more cable length than the APC AP8867US power distribution unit (PDU) 30 AC outlet(s) 0U Black (3 m vs 1.82 m). The Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black has 17,200 VA more load capacity than the APC AP8867US power distribution unit (PDU) 30 AC outlet(s) 0U Black (34500 VA vs 17300 VA). PDU types: Metered on the APC AP8867US power distribution unit (PDU) 30 AC outlet(s) 0U Black, Monitored on the Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black. Mounting: Vertical on the APC AP8867US power distribution unit (PDU) 30 AC outlet(s) 0U Black, Horizontal on the Vertiv MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black.

  • PDU types
    • AP8867US power distribution unit (PDU) 30 AC outlet(s) 0U Black:Metered
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:Monitored
  • Rack capacity
    • AP8867US power distribution unit (PDU) 30 AC outlet(s) 0U Black:0U
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:2U
  • Mounting
    • AP8867US power distribution unit (PDU) 30 AC outlet(s) 0U Black:Vertical
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:Horizontal
  • AC outlets quantity
    • AP8867US power distribution unit (PDU) 30 AC outlet(s) 0U Black:30 AC outlet(s)
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:24 AC outlet(s)
  • AC outlet types
    • AP8867US power distribution unit (PDU) 30 AC outlet(s) 0U Black:C13 coupler
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:C13 coupler, C19 coupler
  • Cable length
    • AP8867US power distribution unit (PDU) 30 AC outlet(s) 0U Black:1.82 m
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:3 m
  • Nominal input voltage
    • AP8867US power distribution unit (PDU) 30 AC outlet(s) 0U Black:208 V
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:200 - 415 V
  • Load capacity
    • AP8867US power distribution unit (PDU) 30 AC outlet(s) 0U Black:17300 VA
    • MN05MDR1-18I6B3-6PS56B0F10-S power distribution unit (PDU) 24 AC outlet(s) 2U Black:34500 VA

Side by side

Differences highlightedShow differences only (off)
Comparison of AP8867US, MN05MDR1-18I6B3-6PS56B0F10-S
37 specifications
Design3 differ
PDU typesDiffersMeteredMonitored
TypeThree-phaseThree-phase
Rack capacityDiffers0U2U
MountingDiffersVerticalHorizontal
Product colourBlackBlack
DisplayKnown for oneUnknown — not stated by the sourceLCD
Ports & interfaces2 differ
AC outlets quantityDiffers30 AC outlet(s)24 AC outlet(s)
Power plugKnown for oneIEC 60309Unknown — not stated by the source
AC outlet typesDiffersC13 couplerC13 coupler, C19 coupler
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source2
Features1 differ
Cable lengthDiffers1.82 m3 m
Daisy chainKnown for oneUnknown — not stated by the sourceYes
Reset buttonKnown for oneUnknown — not stated by the sourceYes
Power2 differ
Nominal input voltageDiffers208 V200 - 415 V
AC input frequency50/60 Hz50/60 Hz
Maximum current60 A60 A
Load capacityDiffers17300 VA34500 VA
Nominal output voltageKnown for oneUnknown — not stated by the source240 V
Maximum powerKnown for oneUnknown — not stated by the source34500 W
Power protection featuresKnown for oneUnknown — not stated by the sourceOver current
Certificatesidentical
CertificationKnown for onecUL Listed UL Listed VCCI Class A TAA complianceUnknown — not stated by the source
Compliance certificatesKnown for oneUnknown — not stated by the sourceCE, cUL, UL, UKCA, RoHS, RCM, Federal Communications Commission (FCC), China RoHS
Operational conditionsidentical
Operating temperature (T-T)Known for one0 - 55 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-25 - 65 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 15240 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers56 mm435 mm
DepthDiffers51 mm740 mm
HeightDiffers1829 mm88 mm
WeightDiffers10.2 kg11.3 kg
Packaging dataidentical
Package weightKnown for one14.1 kgUnknown — not stated by the source
Package widthKnown for one112 mmUnknown — not stated by the source
Package depthKnown for one221 mmUnknown — not stated by the source
Package heightKnown for one2149 mmUnknown — not stated by the source
Management featuresidentical
MonitoringKnown for oneUnknown — not stated by the sourceCurrent, Power, Voltage
Supported network protocolsKnown for oneUnknown — not stated by the sourceDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+, Modbus TCP