Product comparison · 2 power distribution units (pdus)

APC AP8867US power distribution unit (PDU) 30 AC outlet(s) 0U Black vs APC NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets

Add a product
  • 24specifications compared
  • 17differ
  • 7identical
  • 6known for one product only

Key differences

The APC NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets has 2 U more rack capacity than the APC AP8867US power distribution unit (PDU) 30 AC outlet(s) 0U Black (2U vs 0U). The APC NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets has 387 mm more width than the APC AP8867US power distribution unit (PDU) 30 AC outlet(s) 0U Black (443 mm vs 56 mm). The APC NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets has 699 mm more depth than the APC AP8867US power distribution unit (PDU) 30 AC outlet(s) 0U Black (750 mm vs 51 mm). PDU types: Metered on the APC AP8867US power distribution unit (PDU) 30 AC outlet(s) 0U Black, Metered-by-outlet, Switched on the APC NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets. Mounting: Vertical on the APC AP8867US power distribution unit (PDU) 30 AC outlet(s) 0U Black, Horizontal on the APC NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets.

  • PDU types
    • AP8867US power distribution unit (PDU) 30 AC outlet(s) 0U Black:Metered
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:Metered-by-outlet, Switched
  • Rack capacity
    • AP8867US power distribution unit (PDU) 30 AC outlet(s) 0U Black:0U
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:2U
  • Mounting
    • AP8867US power distribution unit (PDU) 30 AC outlet(s) 0U Black:Vertical
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:Horizontal
  • AC outlets quantity
    • AP8867US power distribution unit (PDU) 30 AC outlet(s) 0U Black:30 AC outlet(s)
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:18 AC outlet(s)
  • Power plug
    • AP8867US power distribution unit (PDU) 30 AC outlet(s) 0U Black:IEC 60309
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:IEC309
  • Operating temperature (T-T)
    • AP8867US power distribution unit (PDU) 30 AC outlet(s) 0U Black:0 - 55 °C
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:-5 - 60 °C
  • Storage temperature (T-T)
    • AP8867US power distribution unit (PDU) 30 AC outlet(s) 0U Black:-25 - 65 °C
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:-20 - 60 °C
  • Operating relative humidity (H-H)
    • AP8867US power distribution unit (PDU) 30 AC outlet(s) 0U Black:5 - 95%
    • NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:5 - 90%

Side by side

Differences highlightedShow differences only (on)
Comparison of AP8867US, NetShelter Rack PDU Advanced Switched Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets
30 specifications
Design3 differ
PDU typesDiffersMeteredMetered-by-outlet, Switched
Rack capacityDiffers0U2U
MountingDiffersVerticalHorizontal
Ports & interfaces3 differ
AC outlets quantityDiffers30 AC outlet(s)18 AC outlet(s)
Power plugDiffersIEC 60309IEC309
AC outlet typesDiffersC13 couplerC13 coupler, C15 coupler, C19 coupler, C21 coupler
Featuresidentical
Cable lengthKnown for one1.82 mUnknown — not stated by the source
International Protection (IP) codeKnown for oneUnknown — not stated by the sourceIP44
Poweridentical
Output voltageKnown for oneUnknown — not stated by the source208 V
Certificatesidentical
CertificationKnown for onecUL Listed UL Listed VCCI Class A TAA complianceUnknown — not stated by the source
Operational conditions3 differ
Operating temperature (T-T)Differs0 - 55 °C-5 - 60 °C
Storage temperature (T-T)Differs-25 - 65 °C-20 - 60 °C
Operating relative humidity (H-H)Differs5 - 95%5 - 90%
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Storage relative humidity (H-H)Known for oneUnknown — not stated by the source5 - 95%
Weight & dimensions4 differ
WidthDiffers56 mm443 mm
DepthDiffers51 mm750 mm
HeightDiffers1829 mm85 mm
WeightDiffers10.2 kg16.5 kg
Packaging data4 differ
Package weightDiffers14.1 kg23 kg
Package widthDiffers112 mm600 mm
Package depthDiffers221 mm165 mm
Package heightDiffers2149 mm940 mm