Product comparison · 2 power distribution units (pdus)

APC AP8867US power distribution unit (PDU) 30 AC outlet(s) 0U Black vs APC Easy PDU Switched Zero U 32A

Add a product
  • 24specifications compared
  • 14differ
  • 10identical
  • 9known for one product only

Key differences

The APC Easy PDU Switched Zero U 32A has 22 V more nominal input voltage than the APC AP8867US power distribution unit (PDU) 30 AC outlet(s) 0U Black (230 V vs 208 V). The APC AP8867US power distribution unit (PDU) 30 AC outlet(s) 0U Black has 28 A more maximum current than the APC Easy PDU Switched Zero U 32A (60 A vs 32 A). The APC AP8867US power distribution unit (PDU) 30 AC outlet(s) 0U Black has 9,940 VA more load capacity than the APC Easy PDU Switched Zero U 32A (17300 VA vs 7360 VA). PDU types: Metered on the APC AP8867US power distribution unit (PDU) 30 AC outlet(s) 0U Black, Switched on the APC Easy PDU Switched Zero U 32A. Type: Three-phase on the APC AP8867US power distribution unit (PDU) 30 AC outlet(s) 0U Black, Single-phase on the APC Easy PDU Switched Zero U 32A.

  • PDU types
    • AP8867US power distribution unit (PDU) 30 AC outlet(s) 0U Black:Metered
    • Easy PDU Switched Zero U 32A:Switched
  • Type
    • AP8867US power distribution unit (PDU) 30 AC outlet(s) 0U Black:Three-phase
    • Easy PDU Switched Zero U 32A:Single-phase
  • AC outlets quantity
    • AP8867US power distribution unit (PDU) 30 AC outlet(s) 0U Black:30 AC outlet(s)
    • Easy PDU Switched Zero U 32A:17 AC outlet(s)
  • Nominal input voltage
    • AP8867US power distribution unit (PDU) 30 AC outlet(s) 0U Black:208 V
    • Easy PDU Switched Zero U 32A:230 V
  • Maximum current
    • AP8867US power distribution unit (PDU) 30 AC outlet(s) 0U Black:60 A
    • Easy PDU Switched Zero U 32A:32 A
  • Load capacity
    • AP8867US power distribution unit (PDU) 30 AC outlet(s) 0U Black:17300 VA
    • Easy PDU Switched Zero U 32A:7360 VA
  • Operating temperature (T-T)
    • AP8867US power distribution unit (PDU) 30 AC outlet(s) 0U Black:0 - 55 °C
    • Easy PDU Switched Zero U 32A:-5 - 50 °C
  • Depth
    • AP8867US power distribution unit (PDU) 30 AC outlet(s) 0U Black:51 mm
    • Easy PDU Switched Zero U 32A:62 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of AP8867US, EPDU2132S
33 specifications
Design2 differ
PDU typesDiffersMeteredSwitched
TypeDiffersThree-phaseSingle-phase
Rack capacity0U0U
MountingVerticalVertical
Product colourBlackBlack
Ports & interfaces1 differ
AC outlets quantityDiffers30 AC outlet(s)17 AC outlet(s)
Power plugIEC 60309IEC 60309
AC outlet typesC13 couplerC13 coupler
Power3 differ
Nominal input voltageDiffers208 V230 V
AC input frequency50/60 Hz50/60 Hz
Maximum currentDiffers60 A32 A
Nominal output voltageKnown for oneUnknown — not stated by the source230 V
Output voltageKnown for oneUnknown — not stated by the source230 V
Load capacityDiffers17300 VA7360 VA
Number of phasesKnown for oneUnknown — not stated by the source1
Certificatesidentical
Compliance certificatesKnown for oneUnknown — not stated by the sourceCE, UKCA
CertificationKnown for onecUL Listed UL Listed VCCI Class A TAA complianceUnknown — not stated by the source
Operational conditions1 differ
Operating temperature (T-T)Differs0 - 55 °C-5 - 50 °C
Storage temperature (T-T)-25 - 65 °C-25 - 65 °C
Operating relative humidity (H-H)5 - 95%5 - 95%
Storage relative humidity (H-H)Known for oneUnknown — not stated by the source5 - 95%
Operating altitude0 - 3000 m0 - 3000 m
Non-operating altitudeKnown for one0 - 15240 mUnknown — not stated by the source
Weight & dimensions3 differ
Width56 mm56 mm
DepthDiffers51 mm62 mm
HeightDiffers1829 mm1650 mm
WeightDiffers10.2 kg6.65 kg
Packaging data4 differ
Package weightDiffers14.1 kg8.15 kg
Package widthDiffers112 mm170 mm
Package depthDiffers221 mm1810 mm
Package heightDiffers2149 mm1260 mm
Logistics dataidentical
Total carbon footprint (kg of CO2e)Known for oneUnknown — not stated by the source1310
Featuresidentical
Cable lengthKnown for one1.82 mUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons

All power distribution units (pdus) comparisons