APC AP8867 power distribution unit (PDU) 30 AC outlet(s) 0U Black vs APC Rack PDU 2G, Metered, ZeroU, 23.0kW, 240V, (30) C13 & (12) C19

Add a product
  • 35specifications compared
  • 16differ
  • 19identical
  • 11known for one product only

Key differences

  • AC outlets quantity
    • AP8867 power distribution unit (PDU) 30 AC outlet(s) 0U Black:30 AC outlet(s)
    • Rack PDU 2G, Metered, ZeroU, 23.0kW, 240V, (30) C13 & (12) C19:42 AC outlet(s)
  • AC outlet types
    • AP8867 power distribution unit (PDU) 30 AC outlet(s) 0U Black:C13 coupler
    • Rack PDU 2G, Metered, ZeroU, 23.0kW, 240V, (30) C13 & (12) C19:C13 coupler, C19 coupler
  • Input connection type
    • AP8867 power distribution unit (PDU) 30 AC outlet(s) 0U Black:IEC 309 60A 3P+PE
    • Rack PDU 2G, Metered, ZeroU, 23.0kW, 240V, (30) C13 & (12) C19:IEC 60309 60 A 3P + N + E
  • Cable length
    • AP8867 power distribution unit (PDU) 30 AC outlet(s) 0U Black:1.83 m
    • Rack PDU 2G, Metered, ZeroU, 23.0kW, 240V, (30) C13 & (12) C19:1.82 m
  • Nominal input voltage
    • AP8867 power distribution unit (PDU) 30 AC outlet(s) 0U Black:208 V
    • Rack PDU 2G, Metered, ZeroU, 23.0kW, 240V, (30) C13 & (12) C19:400 3 phases
  • Maximum current
    • AP8867 power distribution unit (PDU) 30 AC outlet(s) 0U Black:60 A
    • Rack PDU 2G, Metered, ZeroU, 23.0kW, 240V, (30) C13 & (12) C19:40 A
  • Nominal output voltage
    • AP8867 power distribution unit (PDU) 30 AC outlet(s) 0U Black:208 V
    • Rack PDU 2G, Metered, ZeroU, 23.0kW, 240V, (30) C13 & (12) C19:240 V
  • Output voltage
    • AP8867 power distribution unit (PDU) 30 AC outlet(s) 0U Black:208 V
    • Rack PDU 2G, Metered, ZeroU, 23.0kW, 240V, (30) C13 & (12) C19:240 V

Side by side

Differences highlightedShow differences only (on)
Comparison of AP8867, AP8888
46 specifications
Ports & interfaces3 differ
AC outlets quantityDiffers30 AC outlet(s)42 AC outlet(s)
AC outlet typesDiffersC13 couplerC13 coupler, C19 coupler
Input connection typeDiffersIEC 309 60A 3P+PEIEC 60309 60 A 3P + N + E
Features1 differ
Cable lengthDiffers1.83 m1.82 m
Power7 differ
Nominal input voltageDiffers208 V400 3 phases
Maximum currentDiffers60 A40 A
Nominal output voltageDiffers208 V240 V
Output voltageDiffers208 V240 V
Load capacityDiffers17300 VA23000 VA
Number of phasesKnown for oneUnknown — not stated by the source3
Maximum input current per phaseDiffers48 A40 A
Maximum total current draw per phaseDiffers48 A32 A
Certificates2 differ
Compliance certificatesDiffersRoHSRoHS, REACH, WEEE
Waste Electrical and Electronic Equipment (WEEE) complianceKnown for oneUnknown — not stated by the sourceYes
CertificationDifferscUL, EN 55022 A, EN 55024, EN 61000-3-2, EN 61000-3-3, FCC-15 A, UL, VCCI AcUL listed; UL listed; VCCI class A
Operational conditions1 differ
Operating relative humidity (H-H)Differs0 - 95%5 - 95%
Weight & dimensions1 differ
WeightDiffers10.2 kg10.1 kg
Technical detailsidentical
Halogen freeKnown for oneUnknown — not stated by the sourceNo
Packaging recycled materialsKnown for oneUnknown — not stated by the sourceRecycled cardboard
Preferred mounting positionKnown for oneUnknown — not stated by the sourceno preference
Removable batteryKnown for oneUnknown — not stated by the sourceYes
Packaging without single use plasticKnown for oneUnknown — not stated by the sourceNo
Sustainable packagingKnown for oneUnknown — not stated by the sourceNo
Take-back systemKnown for oneUnknown — not stated by the sourceNo
Logistics data1 differ
Country of originKnown for oneUnknown — not stated by the sourceIndia
Customs product code (TARIC)Known for oneUnknown — not stated by the source8537109899
Total carbon footprint (kg of CO2e)Differs59943.98413.9248554913295

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.