Product comparison · 2 power distribution units (pdus)

APC AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black vs Vertiv PowerIT rack power distribution unit, 14.4kW, 1P+N+E (IP44), TAA Compliance, RoHS, China RoHS, UL/CE dual listed

Add a product
  • 19specifications compared
  • 16differ
  • 3identical
  • 14known for one product only

Key differences

The Vertiv PowerIT rack power distribution unit, 14.4kW, 1P+N+E (IP44), TAA Compliance, RoHS, China RoHS, UL/CE dual listed has 1.228 m more cable length than the APC AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black (3.048 m vs 1.82 m). The APC AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black has 119,968 V more nominal input voltage than the Vertiv PowerIT rack power distribution unit, 14.4kW, 1P+N+E (IP44), TAA Compliance, RoHS, China RoHS, UL/CE dual listed (120,208 V vs 240 V). The Vertiv PowerIT rack power distribution unit, 14.4kW, 1P+N+E (IP44), TAA Compliance, RoHS, China RoHS, UL/CE dual listed has 43 A more maximum current than the APC AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black (63 A vs 20 A). PDU types: Metered on the APC AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black, Switched on the Vertiv PowerIT rack power distribution unit, 14.4kW, 1P+N+E (IP44), TAA Compliance, RoHS, China RoHS, UL/CE dual listed. Type: Three-phase on the APC AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black, Single-phase on the Vertiv PowerIT rack power distribution unit, 14.4kW, 1P+N+E (IP44), TAA Compliance, RoHS, China RoHS, UL/CE dual listed.

  • PDU types
    • AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black:Metered
    • PowerIT rack power distribution unit, 14.4kW, 1P+N+E (IP44), TAA Compliance, RoHS, China RoHS, UL/CE dual listed:Switched
  • Type
    • AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black:Three-phase
    • PowerIT rack power distribution unit, 14.4kW, 1P+N+E (IP44), TAA Compliance, RoHS, China RoHS, UL/CE dual listed:Single-phase
  • AC outlets quantity
    • AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black:44 AC outlet(s)
    • PowerIT rack power distribution unit, 14.4kW, 1P+N+E (IP44), TAA Compliance, RoHS, China RoHS, UL/CE dual listed:36 AC outlet(s)
  • Power plug
    • AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black:NEMA L21-20P
    • PowerIT rack power distribution unit, 14.4kW, 1P+N+E (IP44), TAA Compliance, RoHS, China RoHS, UL/CE dual listed:Type E / Type F
  • Cable length
    • AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black:1.82 m
    • PowerIT rack power distribution unit, 14.4kW, 1P+N+E (IP44), TAA Compliance, RoHS, China RoHS, UL/CE dual listed:3.048 m
  • Nominal input voltage
    • AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black:120,208 V
    • PowerIT rack power distribution unit, 14.4kW, 1P+N+E (IP44), TAA Compliance, RoHS, China RoHS, UL/CE dual listed:240 V
  • Maximum current
    • AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black:20 A
    • PowerIT rack power distribution unit, 14.4kW, 1P+N+E (IP44), TAA Compliance, RoHS, China RoHS, UL/CE dual listed:63 A
  • Width
    • AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black:56 mm
    • PowerIT rack power distribution unit, 14.4kW, 1P+N+E (IP44), TAA Compliance, RoHS, China RoHS, UL/CE dual listed:88.9 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of AP8861US, VP5U60A0
33 specifications
Design2 differ
PDU typesDiffersMeteredSwitched
TypeDiffersThree-phaseSingle-phase
Rack capacity0U0U
MountingVerticalVertical
Product colourBlackBlack
Ports & interfaces3 differ
AC outlets quantityDiffers44 AC outlet(s)36 AC outlet(s)
Power plugDiffersNEMA L21-20PType E / Type F
AC outlet typesDiffersC13 coupler, C19 coupler, NEMA 5–20C13 coupler, C19 coupler
Serial ports quantityKnown for oneUnknown — not stated by the source1
USB ports quantityKnown for oneUnknown — not stated by the source1
Features1 differ
Cable lengthDiffers1.82 m3.048 m
Management featuresidentical
Management platformKnown for oneUnknown — not stated by the sourceDHCP, HTTP, HTTPS, IPv4, IPv6, LDAP, NTP, RADIUS, RSTP, SSH, SMTP, SNMP (v1/v2c/v3), Syslog, TACACS+
Power2 differ
Nominal input voltageDiffers120,208 V240 V
Maximum currentDiffers20 A63 A
Maximum powerKnown for oneUnknown — not stated by the source14400 W
Power protection featuresKnown for oneUnknown — not stated by the sourceOver current
Load capacityKnown for one5700 VAUnknown — not stated by the source
Certificatesidentical
Compliance certificatesKnown for oneUnknown — not stated by the sourceChina RoHS, RoHS, Trade Agreements Act (TAA)
CertificationKnown for oneUnknown — not stated by the sourceUL Listed, RCM Mark(EMC Only), CE Marked, UKCA Marked, Complies with IEC 62368-1
Weight & dimensions4 differ
WidthDiffers56 mm88.9 mm
DepthDiffers44 mm660 mm
HeightDiffers1791 mm1778 mm
WeightDiffers6.34 kg8.62 kg
Packaging data4 differ
Package weightDiffers7.97 kg8.62 kg
Package widthDiffers107 mm279.4 mm
Package depthDiffers162 mm2209.8 mm
Package heightDiffers2000 mm177.8 mm
Logistics dataidentical
Country of originKnown for oneUnknown — not stated by the sourceUnited States
Operational conditionsidentical
Operating temperature (T-T)Known for one0 - 55 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-25 - 65 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 15240 mUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons

All power distribution units (pdus) comparisons