Product comparison · 2 power distribution units (pdus)

APC AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black vs ATEN PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black

Add a product
  • 17specifications compared
  • 16differ
  • 1identical
  • 24known for one product only

Key differences

The ATEN PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black has 1 U more rack capacity than the APC AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black (1U vs 0U). The ATEN PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black has 1.18 m more cable length than the APC AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black (3 m vs 1.82 m). The APC AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black has 8 A more maximum current than the ATEN PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black (20 A vs 12 A). PDU types: Metered on the APC AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black, Metered, Switched on the ATEN PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black. AC outlets quantity: 44 AC outlet(s) on the APC AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black, 8 AC outlet(s) on the ATEN PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black.

  • PDU types
    • AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black:Metered
    • PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black:Metered, Switched
  • Rack capacity
    • AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black:0U
    • PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black:1U
  • AC outlets quantity
    • AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black:44 AC outlet(s)
    • PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black:8 AC outlet(s)
  • Power plug
    • AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black:NEMA L21-20P
    • PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black:NEMA 5-20P
  • Cable length
    • AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black:1.82 m
    • PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black:3 m
  • Nominal input voltage
    • AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black:120,208 V
    • PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black:100 - 240 V
  • Maximum current
    • AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black:20 A
    • PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black:12 A
  • Load capacity
    • AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black:5700 VA
    • PE8208AV-ATB-G power distribution unit (PDU) 8 AC outlet(s) 1U Black:2400 VA

Side by side

Differences highlightedShow differences only (on)
Comparison of AP8861US, PE8208AV-ATB-G
41 specifications
Design2 differ
PDU typesDiffersMeteredMetered, Switched
Rack capacityDiffers0U1U
TypeKnown for oneThree-phaseUnknown — not stated by the source
MountingKnown for oneVerticalUnknown — not stated by the source
Ports & interfaces3 differ
AC outlets quantityDiffers44 AC outlet(s)8 AC outlet(s)
Power plugDiffersNEMA L21-20PNEMA 5-20P
AC outlet typesDiffersC13 coupler, C19 coupler, NEMA 5–20NEMA 5–20R
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source1
Features1 differ
Cable lengthDiffers1.82 m3 m
Security algorithmsKnown for oneUnknown — not stated by the source128-bit SSL
Password protectionKnown for oneUnknown — not stated by the sourceYes
Management featuresidentical
MonitoringKnown for oneUnknown — not stated by the sourceCurrent, Power, Voltage
Firmware upgradeableKnown for oneUnknown — not stated by the sourceYes
Management protocolsKnown for oneUnknown — not stated by the sourceSNMP Manager V3
Supported network protocolsKnown for oneUnknown — not stated by the sourceTCP/IP, UDP, HTTP, HTTPS, SSL, SMTP, DHCP, NTP, DNS, 10Base-T/100Base-TX, auto sense, Ping, Telnet
Power3 differ
Nominal input voltageDiffers120,208 V100 - 240 V
AC input frequencyKnown for oneUnknown — not stated by the source50/60 Hz
Maximum currentDiffers20 A12 A
Nominal output voltageKnown for oneUnknown — not stated by the source100 - 240 V
Load capacityDiffers5700 VA2400 VA
Maximum powerKnown for oneUnknown — not stated by the source1440 W
Circuit breakerKnown for oneUnknown — not stated by the sourceYes
Certificatesidentical
Compliance certificatesKnown for oneUnknown — not stated by the sourceFederal Communications Commission (FCC)
Sustainabilityidentical
Sustainability complianceKnown for oneUnknown — not stated by the sourceYes
Operational conditions3 differ
Operating temperature (T-T)Differs0 - 55 °C0 - 50 °C
Storage temperature (T-T)Differs-25 - 65 °C-20 - 60 °C
Operating relative humidity (H-H)Differs5 - 95%0 - 80%
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 15240 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers56 mm220.4 mm
DepthDiffers44 mm432.4 mm
HeightDiffers1791 mm44 mm
WeightDiffers6.34 kg2.84 kg
Packaging contentidentical
Cables includedKnown for oneUnknown — not stated by the sourceAC
ManualKnown for oneUnknown — not stated by the sourceYes
Rack mount kitKnown for oneUnknown — not stated by the sourceYes
Packaging dataidentical
Package weightKnown for one7.97 kgUnknown — not stated by the source
Package widthKnown for one107 mmUnknown — not stated by the source
Package depthKnown for one162 mmUnknown — not stated by the source
Package heightKnown for one2000 mmUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons

All power distribution units (pdus) comparisons