Key differences

The APC NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets has 2 U more rack capacity than the APC AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black (2U vs 0U). The APC AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black has 120,000 V more nominal input voltage than the APC NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets (120,208 V vs 208 V). The APC NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets has 40 A more maximum current than the APC AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black (60 A vs 20 A). Mounting: Vertical on the APC AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black, Horizontal on the APC NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets. AC outlets quantity: 44 AC outlet(s) on the APC AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black, 18 AC outlet(s) on the APC NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets.

  • Rack capacity
    • AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black:0U
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:2U
  • Mounting
    • AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black:Vertical
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:Horizontal
  • AC outlets quantity
    • AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black:44 AC outlet(s)
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:18 AC outlet(s)
  • Power plug
    • AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black:NEMA L21-20P
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:IEC309
  • Nominal input voltage
    • AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black:120,208 V
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:208 V
  • Maximum current
    • AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black:20 A
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:60 A
  • Load capacity
    • AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black:5700 VA
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:17300 VA
  • Operating temperature (T-T)
    • AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black:0 - 55 °C
    • NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets:-5 - 60 °C

Side by side

Differences highlightedShow differences only (off)
Comparison of AP8861US, NetShelter Rack PDU Advanced Metered, 2U, 3 Phase, 208V, 17.3kVA 60A, 18 Outlets
28 specifications
Design2 differ
PDU typesMeteredMetered
TypeThree-phaseThree-phase
Rack capacityDiffers0U2U
MountingDiffersVerticalHorizontal
Product colourBlackBlack
Ports & interfaces3 differ
AC outlets quantityDiffers44 AC outlet(s)18 AC outlet(s)
Power plugDiffersNEMA L21-20PIEC309
AC outlet typesDiffersC13 coupler, C19 coupler, NEMA 5–20C13 coupler, C15 coupler, C19 coupler, C21 coupler
Featuresidentical
International Protection (IP) codeKnown for oneUnknown — not stated by the sourceIP44
Cable lengthKnown for one1.82 mUnknown — not stated by the source
Power3 differ
Nominal input voltageDiffers120,208 V208 V
Maximum currentDiffers20 A60 A
Output voltageKnown for oneUnknown — not stated by the source208 V
Load capacityDiffers5700 VA17300 VA
Operational conditions3 differ
Operating temperature (T-T)Differs0 - 55 °C-5 - 60 °C
Storage temperature (T-T)Differs-25 - 65 °C-20 - 60 °C
Operating relative humidity (H-H)Differs5 - 95%5 - 90%
Storage relative humidity (H-H)Known for oneUnknown — not stated by the source5 - 95%
Non-operating altitude0 - 15240 m0 - 15240 m
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers56 mm443 mm
DepthDiffers44 mm750 mm
HeightDiffers1791 mm85 mm
WeightDiffers6.34 kg15.7 kg
Packaging data4 differ
Package weightDiffers7.97 kg22.2 kg
Package widthDiffers107 mm600 mm
Package depthDiffers162 mm165 mm
Package heightDiffers2000 mm940 mm

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.