Product comparison · 2 power distribution units (pdus)

APC AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black vs APC APDU11452MO power distribution unit (PDU) 42 AC outlet(s) 0U Black

Add a product
  • 20specifications compared
  • 14differ
  • 6identical
  • 10known for one product only

Key differences

The APC APDU11452MO power distribution unit (PDU) 42 AC outlet(s) 0U Black has 1.18 m more cable length than the APC AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black (3 m vs 1.82 m). The APC APDU11452MO power distribution unit (PDU) 42 AC outlet(s) 0U Black has 40 A more maximum current than the APC AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black (60 A vs 20 A). The APC APDU11452MO power distribution unit (PDU) 42 AC outlet(s) 0U Black has 11,600 VA more load capacity than the APC AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black (17300 VA vs 5700 VA). AC outlets quantity: 44 AC outlet(s) on the APC AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black, 42 AC outlet(s) on the APC APDU11452MO power distribution unit (PDU) 42 AC outlet(s) 0U Black. AC outlet types: C13 coupler, C19 coupler, NEMA 5–20 on the APC AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black, C13 coupler, C19 coupler on the APC APDU11452MO power distribution unit (PDU) 42 AC outlet(s) 0U Black.

  • AC outlets quantity
    • AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black:44 AC outlet(s)
    • APDU11452MO power distribution unit (PDU) 42 AC outlet(s) 0U Black:42 AC outlet(s)
  • Cable length
    • AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black:1.82 m
    • APDU11452MO power distribution unit (PDU) 42 AC outlet(s) 0U Black:3 m
  • Nominal input voltage
    • AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black:120,208 V
    • APDU11452MO power distribution unit (PDU) 42 AC outlet(s) 0U Black:200 - 240 V
  • Maximum current
    • AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black:20 A
    • APDU11452MO power distribution unit (PDU) 42 AC outlet(s) 0U Black:60 A
  • Load capacity
    • AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black:5700 VA
    • APDU11452MO power distribution unit (PDU) 42 AC outlet(s) 0U Black:17300 VA
  • Operating temperature (T-T)
    • AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black:0 - 55 °C
    • APDU11452MO power distribution unit (PDU) 42 AC outlet(s) 0U Black:-5 - 60 °F
  • Depth
    • AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black:44 mm
    • APDU11452MO power distribution unit (PDU) 42 AC outlet(s) 0U Black:75 mm
  • Height
    • AP8861US power distribution unit (PDU) 44 AC outlet(s) 0U Black:1791 mm
    • APDU11452MO power distribution unit (PDU) 42 AC outlet(s) 0U Black:1780 mm

Side by side

Differences highlightedShow differences only (off)
Comparison of AP8861US, APDU11452MO
30 specifications
Designidentical
PDU typesMeteredMetered
TypeKnown for oneThree-phaseUnknown — not stated by the source
Rack capacity0U0U
MountingVerticalVertical
Product colourBlackBlack
Ports & interfaces2 differ
AC outlets quantityDiffers44 AC outlet(s)42 AC outlet(s)
Power plugKnown for oneNEMA L21-20PUnknown — not stated by the source
AC outlet typesDiffersC13 coupler, C19 coupler, NEMA 5–20C13 coupler, C19 coupler
Features1 differ
Cable lengthDiffers1.82 m3 m
Power3 differ
Nominal input voltageDiffers120,208 V200 - 240 V
Maximum currentDiffers20 A60 A
Load capacityDiffers5700 VA17300 VA
AC input frequencyKnown for oneUnknown — not stated by the source50/60 Hz
Nominal output voltageKnown for oneUnknown — not stated by the source208 V
Output voltageKnown for oneUnknown — not stated by the source208 V
Maximum powerKnown for oneUnknown — not stated by the source43500 W
Operational conditions1 differ
Operating temperature (T-T)Differs0 - 55 °C-5 - 60 °F
Storage temperature (T-T)Known for one-25 - 65 °CUnknown — not stated by the source
Operating relative humidity (H-H)5 - 95%5 - 95%
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 15240 mUnknown — not stated by the source
Operating temperature (charge) (T-T)Known for oneUnknown — not stated by the source-25 - 65 °C
Weight & dimensions3 differ
Width56 mm56 mm
DepthDiffers44 mm75 mm
HeightDiffers1791 mm1780 mm
WeightDiffers6.34 kg11.1 kg
Packaging data4 differ
Package weightDiffers7.97 kg14.1 kg
Package widthDiffers107 mm132 mm
Package depthDiffers162 mm262 mm
Package heightDiffers2000 mm1980 mm

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.