Product comparison · 2 power distribution units (pdus)

APC Rack PDU, Basic, Zero U, 30A, 200/208V, (20)C13 & (4)C19 vs Lindy 32623 power distribution unit (PDU) 8 AC outlet(s) 1U Black

Add a product
  • 22specifications compared
  • 21differ
  • 1identical
  • 29known for one product only

Key differences

The Lindy 32623 power distribution unit (PDU) 8 AC outlet(s) 1U Black has 1 U more rack capacity than the APC Rack PDU, Basic, Zero U, 30A, 200/208V, (20)C13 & (4)C19 (1U vs 0U). The APC Rack PDU, Basic, Zero U, 30A, 200/208V, (20)C13 & (4)C19 has 14 A more maximum current than the Lindy 32623 power distribution unit (PDU) 8 AC outlet(s) 1U Black (30 A vs 16 A). The Lindy 32623 power distribution unit (PDU) 8 AC outlet(s) 1U Black has 380 mm more width than the APC Rack PDU, Basic, Zero U, 30A, 200/208V, (20)C13 & (4)C19 (436 mm vs 56 mm). PDU types: Basic on the APC Rack PDU, Basic, Zero U, 30A, 200/208V, (20)C13 & (4)C19, Metered, Switched on the Lindy 32623 power distribution unit (PDU) 8 AC outlet(s) 1U Black. AC outlets quantity: 24 AC outlet(s) on the APC Rack PDU, Basic, Zero U, 30A, 200/208V, (20)C13 & (4)C19, 8 AC outlet(s) on the Lindy 32623 power distribution unit (PDU) 8 AC outlet(s) 1U Black.

  • PDU types
    • Rack PDU, Basic, Zero U, 30A, 200/208V, (20)C13 & (4)C19:Basic
    • 32623 power distribution unit (PDU) 8 AC outlet(s) 1U Black:Metered, Switched
  • Rack capacity
    • Rack PDU, Basic, Zero U, 30A, 200/208V, (20)C13 & (4)C19:0U
    • 32623 power distribution unit (PDU) 8 AC outlet(s) 1U Black:1U
  • AC outlets quantity
    • Rack PDU, Basic, Zero U, 30A, 200/208V, (20)C13 & (4)C19:24 AC outlet(s)
    • 32623 power distribution unit (PDU) 8 AC outlet(s) 1U Black:8 AC outlet(s)
  • Power plug
    • Rack PDU, Basic, Zero U, 30A, 200/208V, (20)C13 & (4)C19:NEMA L6-30P
    • 32623 power distribution unit (PDU) 8 AC outlet(s) 1U Black:C20 coupler
  • AC outlet types
    • Rack PDU, Basic, Zero U, 30A, 200/208V, (20)C13 & (4)C19:NEMA L6-30P
    • 32623 power distribution unit (PDU) 8 AC outlet(s) 1U Black:C13 coupler
  • Nominal input voltage
    • Rack PDU, Basic, Zero U, 30A, 200/208V, (20)C13 & (4)C19:200; 208; 230 V
    • 32623 power distribution unit (PDU) 8 AC outlet(s) 1U Black:110 - 250 V
  • AC input frequency
    • Rack PDU, Basic, Zero U, 30A, 200/208V, (20)C13 & (4)C19:50-60 Hz
    • 32623 power distribution unit (PDU) 8 AC outlet(s) 1U Black:50/60 Hz
  • Maximum current
    • Rack PDU, Basic, Zero U, 30A, 200/208V, (20)C13 & (4)C19:30 A
    • 32623 power distribution unit (PDU) 8 AC outlet(s) 1U Black:16 A

Side by side

Differences highlightedShow differences only (off)
Comparison of AP7541, 32623
51 specifications
Design2 differ
PDU typesDiffersBasicMetered, Switched
TypeKnown for oneSingle-phaseUnknown — not stated by the source
Rack capacityDiffers0U1U
MountingKnown for oneVerticalUnknown — not stated by the source
Product colourBlackBlack
Housing materialKnown for oneUnknown — not stated by the sourceMetal
Ports & interfaces3 differ
AC outlets quantityDiffers24 AC outlet(s)8 AC outlet(s)
Power plugDiffersNEMA L6-30PC20 coupler
AC outlet typesDiffersNEMA L6-30PC13 coupler
Input connection typeKnown for oneNEMA L6-30PUnknown — not stated by the source
Output connectionsKnown for one(20) IEC 320 C13 (4) IEC 320 C19Unknown — not stated by the source
Serial ports quantityKnown for oneUnknown — not stated by the source1
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source4
Featuresidentical
Cable lengthKnown for one3 mUnknown — not stated by the source
Power3 differ
Nominal input voltageDiffers200; 208; 230 V110 - 250 V
AC input frequencyDiffers50-60 Hz50/60 Hz
Maximum currentDiffers30 A16 A
Output voltageKnown for one200 V; 208 VUnknown — not stated by the source
Load capacityKnown for one4992 VAUnknown — not stated by the source
Maximum input current per phaseKnown for one30 AUnknown — not stated by the source
Maximum total current draw per phaseKnown for one24 AUnknown — not stated by the source
Maximum powerKnown for oneUnknown — not stated by the source2500 W
Certificates1 differ
Compliance certificatesDiffersRoHS, REACH, WEEECE, UKCA, RoHS, REACH, Electromagnetic Compatibility (EMC), Low Voltage Directive (LVD), Federal Communications Commission (FCC)
Waste Electrical and Electronic Equipment (WEEE) complianceKnown for oneYesUnknown — not stated by the source
CertificationKnown for onecUL,CSA C22.2 No. 60950-1-03,METI Denan,UL 60950-1,ULUnknown — not stated by the source
Operational conditions3 differ
Operating temperature (T-T)Differs0 - 45 °C-5 - 55 °C
Storage temperature (T-T)Differs-25 - 65 °C-20 - 70 °C
Operating relative humidity (H-H)Differs0 - 95%0 - 80%
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 15240 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers56 mm436 mm
DepthDiffers44 mm225 mm
HeightDiffers1619 mm44 mm
WeightDiffers5.57 kg1.1 kg
Packaging content1 differ
Cables includedDiffersPowerPower, Serial
ManualKnown for oneUnknown — not stated by the sourceYes
Packaging data4 differ
Package weightDiffers6.48 kg2.5 kg
Package widthDiffers127 mm540 mm
Package depthDiffers152 mm422 mm
Package heightDiffers2121 mm87 mm
Technical detailsidentical
Halogen freeKnown for oneNoUnknown — not stated by the source
Packaging recycled materialsKnown for oneRecycled cardboardUnknown — not stated by the source
Preferred mounting positionKnown for oneno preferenceUnknown — not stated by the source
Packaging without single use plasticKnown for oneNoUnknown — not stated by the source
Sustainable packagingKnown for oneNoUnknown — not stated by the source
Take-back systemKnown for oneNoUnknown — not stated by the source
Logistics dataidentical
Country of originKnown for oneIndiaUnknown — not stated by the source
Customs product code (TARIC)Known for one8544429090Unknown — not stated by the source
Total carbon footprint (kg of CO2e)Known for one3936.6696350091Unknown — not stated by the source
Management featuresidentical
MonitoringKnown for oneUnknown — not stated by the sourceVoltage, Current, Power

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.