Product comparison · 2 power distribution units (pdus)

APC Rack PDU, Basic, Zero U, 30A, 200/208V, (20)C13 & (4)C19 vs APC NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet

Add a product
  • 29specifications compared
  • 19differ
  • 10identical
  • 24known for one product only

Key differences

The APC NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet has 30 A more maximum current than the APC Rack PDU, Basic, Zero U, 30A, 200/208V, (20)C13 & (4)C19 (60 A vs 30 A). The APC NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet has 29,608 VA more load capacity than the APC Rack PDU, Basic, Zero U, 30A, 200/208V, (20)C13 & (4)C19 (34600 VA vs 4992 VA). The APC NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet has 31 mm more depth than the APC Rack PDU, Basic, Zero U, 30A, 200/208V, (20)C13 & (4)C19 (75 mm vs 44 mm). PDU types: Basic on the APC Rack PDU, Basic, Zero U, 30A, 200/208V, (20)C13 & (4)C19, Metered on the APC NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet. Type: Single-phase on the APC Rack PDU, Basic, Zero U, 30A, 200/208V, (20)C13 & (4)C19, Three-phase on the APC NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet.

  • PDU types
    • Rack PDU, Basic, Zero U, 30A, 200/208V, (20)C13 & (4)C19:Basic
    • NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:Metered
  • Type
    • Rack PDU, Basic, Zero U, 30A, 200/208V, (20)C13 & (4)C19:Single-phase
    • NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:Three-phase
  • AC outlets quantity
    • Rack PDU, Basic, Zero U, 30A, 200/208V, (20)C13 & (4)C19:24 AC outlet(s)
    • NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:42 AC outlet(s)
  • Input connection type
    • Rack PDU, Basic, Zero U, 30A, 200/208V, (20)C13 & (4)C19:NEMA L6-30P
    • NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:IEC 60309 30 A 3P + N + PE
  • Nominal input voltage
    • Rack PDU, Basic, Zero U, 30A, 200/208V, (20)C13 & (4)C19:200; 208; 230 V
    • NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:415 3 phases; 400 3 phases
  • AC input frequency
    • Rack PDU, Basic, Zero U, 30A, 200/208V, (20)C13 & (4)C19:50-60 Hz
    • NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:50/60 Hz
  • Maximum current
    • Rack PDU, Basic, Zero U, 30A, 200/208V, (20)C13 & (4)C19:30 A
    • NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:60 A
  • Output voltage
    • Rack PDU, Basic, Zero U, 30A, 200/208V, (20)C13 & (4)C19:200 V; 208 V
    • NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet:240 V

Side by side

Differences highlightedShow differences only (off)
Comparison of AP7541, NetShelter Rack PDU Advanced Gen 2, Metered Outlet, 3Phase, 22.1kW 400V 32A or 17.3kW 415V 30A, 530P6, 48 Outlet
53 specifications
Design2 differ
PDU typesDiffersBasicMetered
TypeDiffersSingle-phaseThree-phase
Rack capacity0U0U
MountingKnown for oneVerticalUnknown — not stated by the source
Product colourBlackBlack
Ports & interfaces3 differ
AC outlets quantityDiffers24 AC outlet(s)42 AC outlet(s)
Power plugKnown for oneNEMA L6-30PUnknown — not stated by the source
AC outlet typesDiffersNEMA L6-30PC13 coupler, C15 coupler, C19 coupler, C21 coupler
Input connection typeDiffersNEMA L6-30PIEC 60309 30 A 3P + N + PE
Output connectionsKnown for one(20) IEC 320 C13 (4) IEC 320 C19Unknown — not stated by the source
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source5
USB ports quantityKnown for oneUnknown — not stated by the source1
Featuresidentical
Cable length3 m3 m
Power5 differ
Nominal input voltageDiffers200; 208; 230 V415 3 phases; 400 3 phases
AC input frequencyDiffers50-60 Hz50/60 Hz
Maximum currentDiffers30 A60 A
Output voltageDiffers200 V; 208 V240 V
Load capacityDiffers4992 VA34600 VA
Maximum input current per phaseKnown for one30 AUnknown — not stated by the source
Maximum total current draw per phaseKnown for one24 AUnknown — not stated by the source
Nominal output voltageKnown for oneUnknown — not stated by the source400 V
Number of phasesKnown for oneUnknown — not stated by the source3
Battery replacement accessibilityKnown for oneUnknown — not stated by the sourceNon-removable
Certificates1 differ
Compliance certificatesRoHS, REACH, WEEERoHS, REACH, WEEE
Waste Electrical and Electronic Equipment (WEEE) complianceYesYes
CertificationDifferscUL,CSA C22.2 No. 60950-1-03,METI Denan,UL 60950-1,ULUKCA
Operational conditionsidentical
Operating temperature (T-T)Known for one0 - 45 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one-25 - 65 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 15240 mUnknown — not stated by the source
Weight & dimensions3 differ
Width56 mm56 mm
DepthDiffers44 mm75 mm
HeightDiffers1619 mm1780 mm
WeightDiffers5.57 kg9.6 kg
Packaging contentidentical
Cables includedKnown for onePowerUnknown — not stated by the source
Packaging data4 differ
Package weightDiffers6.48 kg17 kg
Package widthDiffers127 mm132 mm
Package depthDiffers152 mm262 mm
Package heightDiffers2121 mm2110 mm
Technical detailsidentical
Halogen freeKnown for oneNoUnknown — not stated by the source
Packaging recycled materialsKnown for oneRecycled cardboardUnknown — not stated by the source
Preferred mounting positionno preferenceno preference
Packaging without single use plasticNoNo
Sustainable packagingNoNo
Take-back systemNoNo
Removable batteryKnown for oneUnknown — not stated by the sourceNo
SCIP numberKnown for oneUnknown — not stated by the source31346aed-552c-4a16-81d9-e683a383b6da
Logistics data1 differ
Country of originKnown for oneIndiaUnknown — not stated by the source
Customs product code (TARIC)Differs85444290908537109899
Total carbon footprint (kg of CO2e)Known for one3936.6696350091Unknown — not stated by the source
Management featuresidentical
Management platformKnown for oneUnknown — not stated by the sourceNMC3

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.