Product comparison · 2 power distribution units (pdus)

APC AP4434 power distribution unit (PDU) 9 AC outlet(s) 1U Black vs APC AP4450 power distribution unit (PDU) 10 AC outlet(s) 1U Black

Add a product
  • 21specifications compared
  • 9differ
  • 12identical
  • 4known for one product only

Key differences

  • AC outlets quantity
    • AP4434 power distribution unit (PDU) 9 AC outlet(s) 1U Black:9 AC outlet(s)
    • AP4450 power distribution unit (PDU) 10 AC outlet(s) 1U Black:10 AC outlet(s)
  • AC outlet types
    • AP4434 power distribution unit (PDU) 9 AC outlet(s) 1U Black:C13 coupler, C19 coupler
    • AP4450 power distribution unit (PDU) 10 AC outlet(s) 1U Black:NEMA 5–15R
  • Nominal input voltage
    • AP4434 power distribution unit (PDU) 9 AC outlet(s) 1U Black:208 V
    • AP4450 power distribution unit (PDU) 10 AC outlet(s) 1U Black:100-120 V
  • Maximum current
    • AP4434 power distribution unit (PDU) 9 AC outlet(s) 1U Black:20 A
    • AP4450 power distribution unit (PDU) 10 AC outlet(s) 1U Black:15 A
  • Nominal output voltage
    • AP4434 power distribution unit (PDU) 9 AC outlet(s) 1U Black:208 V
    • AP4450 power distribution unit (PDU) 10 AC outlet(s) 1U Black:100-120 V
  • Maximum total current draw per phase
    • AP4434 power distribution unit (PDU) 9 AC outlet(s) 1U Black:20 A
    • AP4450 power distribution unit (PDU) 10 AC outlet(s) 1U Black:15 A
  • Operating relative humidity (H-H)
    • AP4434 power distribution unit (PDU) 9 AC outlet(s) 1U Black:5 - 95%
    • AP4450 power distribution unit (PDU) 10 AC outlet(s) 1U Black:0 - 95%
  • Storage relative humidity (H-H)
    • AP4434 power distribution unit (PDU) 9 AC outlet(s) 1U Black:5 - 95%
    • AP4450 power distribution unit (PDU) 10 AC outlet(s) 1U Black:0 - 95%

Side by side

Differences highlightedShow differences only (off)
Comparison of AP4434, AP4450
25 specifications
Designidentical
PDU typesSwitchedSwitched
Rack capacity1U1U
MountingHorizontalHorizontal
Product colourBlackBlack
Ports & interfaces2 differ
AC outlets quantityDiffers9 AC outlet(s)10 AC outlet(s)
AC outlet typesDiffersC13 coupler, C19 couplerNEMA 5–15R
Input connection typeKnown for oneIEC-320 C20Unknown — not stated by the source
Output connectionsKnown for one(1) IEC 320 C19 (Battery Backup) (8) IEC 320 C13 (Battery Backup)Unknown — not stated by the source
Power4 differ
Nominal input voltageDiffers208 V100-120 V
AC input frequency50 - 60 Hz50 - 60 Hz
Maximum currentDiffers20 A15 A
Nominal output voltageDiffers208 V100-120 V
Maximum total current draw per phaseDiffers20 A15 A
Load capacityKnown for oneUnknown — not stated by the source1440 VA
Certificatesidentical
Compliance certificatesKnown for oneRoHSUnknown — not stated by the source
Operational conditions2 differ
Operating temperature (T-T)-5 - 45 °C-5 - 45 °C
Storage temperature (T-T)-25 - 65 °C-25 - 65 °C
Operating relative humidity (H-H)Differs5 - 95%0 - 95%
Storage relative humidity (H-H)Differs5 - 95%0 - 95%
Operating altitude0 - 3000 m0 - 3000 m
Non-operating altitude0 - 15000 m0 - 15000 m
Weight & dimensions1 differ
Width44 mm44 mm
Depth236 mm236 mm
Height432 mm432 mm
WeightDiffers3.74 kg4.4 kg