Product comparison · 2 power distribution units (pdus)

APC AP4432 power distribution unit (PDU) 18 AC outlet(s) 2U Black vs APC AP4433 power distribution unit (PDU) 12 AC outlet(s) 1U Black

Add a product
  • 24specifications compared
  • 9differ
  • 15identical
  • 1known for one product only

Key differences

  • Rack capacity
    • AP4432 power distribution unit (PDU) 18 AC outlet(s) 2U Black:2U
    • AP4433 power distribution unit (PDU) 12 AC outlet(s) 1U Black:1U
  • AC outlets quantity
    • AP4432 power distribution unit (PDU) 18 AC outlet(s) 2U Black:18 AC outlet(s)
    • AP4433 power distribution unit (PDU) 12 AC outlet(s) 1U Black:12 AC outlet(s)
  • AC outlet types
    • AP4432 power distribution unit (PDU) 18 AC outlet(s) 2U Black:C13 coupler, C19 coupler
    • AP4433 power distribution unit (PDU) 12 AC outlet(s) 1U Black:C13 coupler
  • Input connection type
    • AP4432 power distribution unit (PDU) 18 AC outlet(s) 2U Black:NEMA L6-30P
    • AP4433 power distribution unit (PDU) 12 AC outlet(s) 1U Black:C14
  • Maximum current
    • AP4432 power distribution unit (PDU) 18 AC outlet(s) 2U Black:30 A
    • AP4433 power distribution unit (PDU) 12 AC outlet(s) 1U Black:12 A
  • Maximum total current draw per phase
    • AP4432 power distribution unit (PDU) 18 AC outlet(s) 2U Black:30 A
    • AP4433 power distribution unit (PDU) 12 AC outlet(s) 1U Black:12 A
  • Width
    • AP4432 power distribution unit (PDU) 18 AC outlet(s) 2U Black:88 mm
    • AP4433 power distribution unit (PDU) 12 AC outlet(s) 1U Black:44 mm
  • Weight
    • AP4432 power distribution unit (PDU) 18 AC outlet(s) 2U Black:6.58 kg
    • AP4433 power distribution unit (PDU) 12 AC outlet(s) 1U Black:3.74 kg

Side by side

Differences highlightedShow differences only (on)
Comparison of AP4432, AP4433
25 specifications
Design1 differ
Rack capacityDiffers2U1U
Ports & interfaces4 differ
AC outlets quantityDiffers18 AC outlet(s)12 AC outlet(s)
AC outlet typesDiffersC13 coupler, C19 couplerC13 coupler
Input connection typeDiffersNEMA L6-30PC14
Output connectionsDiffers(2) IEC 320 C19 (Battery Backup) (16) IEC 320 C13 (Battery Backup)(12) IEC 320 C13 (Battery Backup)
Power2 differ
Maximum currentDiffers30 A12 A
Maximum total current draw per phaseDiffers30 A12 A
Power protection featuresKnown for oneOverloadUnknown — not stated by the source
Weight & dimensions2 differ
WidthDiffers88 mm44 mm
WeightDiffers6.58 kg3.74 kg

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.