Product comparison · 2 power distribution units (pdus)

APC AP4430 power distribution unit (PDU) 9 AC outlet(s) 1U Black vs APC AP4450 power distribution unit (PDU) 10 AC outlet(s) 1U Black

Add a product
  • 20specifications compared
  • 9differ
  • 11identical
  • 4known for one product only

Key differences

  • AC outlets quantity
    • AP4430 power distribution unit (PDU) 9 AC outlet(s) 1U Black:9 AC outlet(s)
    • AP4450 power distribution unit (PDU) 10 AC outlet(s) 1U Black:10 AC outlet(s)
  • Nominal input voltage
    • AP4430 power distribution unit (PDU) 9 AC outlet(s) 1U Black:208 V
    • AP4450 power distribution unit (PDU) 10 AC outlet(s) 1U Black:100-120 V
  • Maximum current
    • AP4430 power distribution unit (PDU) 9 AC outlet(s) 1U Black:20 A
    • AP4450 power distribution unit (PDU) 10 AC outlet(s) 1U Black:15 A
  • Nominal output voltage
    • AP4430 power distribution unit (PDU) 9 AC outlet(s) 1U Black:208 V
    • AP4450 power distribution unit (PDU) 10 AC outlet(s) 1U Black:100-120 V
  • Maximum total current draw per phase
    • AP4430 power distribution unit (PDU) 9 AC outlet(s) 1U Black:20 A
    • AP4450 power distribution unit (PDU) 10 AC outlet(s) 1U Black:15 A
  • Operating relative humidity (H-H)
    • AP4430 power distribution unit (PDU) 9 AC outlet(s) 1U Black:5 - 95%
    • AP4450 power distribution unit (PDU) 10 AC outlet(s) 1U Black:0 - 95%
  • Storage relative humidity (H-H)
    • AP4430 power distribution unit (PDU) 9 AC outlet(s) 1U Black:5 - 95%
    • AP4450 power distribution unit (PDU) 10 AC outlet(s) 1U Black:0 - 95%
  • Weight
    • AP4430 power distribution unit (PDU) 9 AC outlet(s) 1U Black:4.83 kg
    • AP4450 power distribution unit (PDU) 10 AC outlet(s) 1U Black:4.4 kg

Side by side

Differences highlightedShow differences only (off)
Comparison of AP4430, AP4450
24 specifications
Designidentical
PDU typesSwitchedSwitched
Rack capacity1U1U
Product colourBlackBlack
MountingKnown for oneUnknown — not stated by the sourceHorizontal
Ports & interfaces2 differ
AC outlets quantityDiffers9 AC outlet(s)10 AC outlet(s)
AC outlet typesDiffersC13 coupler, C19 coupler, NEMA 6–20PNEMA 5–15R
Output connectionsKnown for one(1) IEC 320 C19 (Battery Backup) (8) IEC 320 C13 (Battery Backup)Unknown — not stated by the source
Power4 differ
Nominal input voltageDiffers208 V100-120 V
AC input frequency50 - 60 Hz50 - 60 Hz
Maximum currentDiffers20 A15 A
Nominal output voltageDiffers208 V100-120 V
Maximum total current draw per phaseDiffers20 A15 A
Load capacityKnown for oneUnknown — not stated by the source1440 VA
Certificatesidentical
Compliance certificatesKnown for oneRoHSUnknown — not stated by the source
Operational conditions2 differ
Operating temperature (T-T)-5 - 45 °C-5 - 45 °C
Storage temperature (T-T)-25 - 65 °C-25 - 65 °C
Operating relative humidity (H-H)Differs5 - 95%0 - 95%
Storage relative humidity (H-H)Differs5 - 95%0 - 95%
Operating altitude0 - 3000 m0 - 3000 m
Non-operating altitude0 - 15000 m0 - 15000 m
Weight & dimensions1 differ
Width44 mm44 mm
Depth236 mm236 mm
Height432 mm432 mm
WeightDiffers4.83 kg4.4 kg

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons

All power distribution units (pdus) comparisons