Product comparison · 2 power distribution units (pdus)

APC 300KVA PDU vs APC SURT014 power distribution unit (PDU) 6 AC outlet(s) White

Add a product
  • 9specifications compared
  • 8differ
  • 1identical
  • 17known for one product only

Key differences

The APC 300KVA PDU has 272 V more nominal input voltage than the APC SURT014 power distribution unit (PDU) 6 AC outlet(s) White (480 V vs 208 V). The APC 300KVA PDU has 341 A more maximum input current per phase than the APC SURT014 power distribution unit (PDU) 6 AC outlet(s) White (361 A vs 20 A). The APC 300KVA PDU has 1,022 mm more width than the APC SURT014 power distribution unit (PDU) 6 AC outlet(s) White (1143 mm vs 121 mm). Product colour: Black on the APC 300KVA PDU, White on the APC SURT014 power distribution unit (PDU) 6 AC outlet(s) White. AC input frequency: 60 Hz on the APC 300KVA PDU, 50 - 60 Hz on the APC SURT014 power distribution unit (PDU) 6 AC outlet(s) White.

  • Product colour
    • 300KVA PDU:Black
    • SURT014 power distribution unit (PDU) 6 AC outlet(s) White:White
  • Nominal input voltage
    • 300KVA PDU:480 V
    • SURT014 power distribution unit (PDU) 6 AC outlet(s) White:208 V
  • AC input frequency
    • 300KVA PDU:60 Hz
    • SURT014 power distribution unit (PDU) 6 AC outlet(s) White:50 - 60 Hz
  • Maximum input current per phase
    • 300KVA PDU:361 A
    • SURT014 power distribution unit (PDU) 6 AC outlet(s) White:20 A
  • Width
    • 300KVA PDU:1143 mm
    • SURT014 power distribution unit (PDU) 6 AC outlet(s) White:121 mm
  • Depth
    • 300KVA PDU:978 mm
    • SURT014 power distribution unit (PDU) 6 AC outlet(s) White:51 mm
  • Height
    • 300KVA PDU:2070 mm
    • SURT014 power distribution unit (PDU) 6 AC outlet(s) White:190 mm
  • Weight
    • 300KVA PDU:1318.2 kg
    • SURT014 power distribution unit (PDU) 6 AC outlet(s) White:910 g

Side by side

Differences highlightedShow differences only (off)
Comparison of 300KVA PDU, SURT014
26 specifications
Design1 differ
PDU typesBasicBasic
Product colourDiffersBlackWhite
Power3 differ
Nominal input voltageDiffers480 V208 V
AC input frequencyDiffers60 Hz50 - 60 Hz
Nominal output voltageKnown for one120-208 VUnknown — not stated by the source
Load capacityKnown for one300000 VAUnknown — not stated by the source
Maximum input current per phaseDiffers361 A20 A
Certificatesidentical
CertificationKnown for oneUL 60950Unknown — not stated by the source
Operational conditionsidentical
Operating temperature (T-T)Known for one0 - 40 °CUnknown — not stated by the source
Storage temperature (T-T)Known for one0 - 45 °CUnknown — not stated by the source
Operating relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Storage relative humidity (H-H)Known for one0 - 95%Unknown — not stated by the source
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Non-operating altitudeKnown for one0 - 9000 mUnknown — not stated by the source
Weight & dimensions4 differ
WidthDiffers1143 mm121 mm
DepthDiffers978 mm51 mm
HeightDiffers2070 mm190 mm
WeightDiffers1318.2 kg910 g
Ports & interfacesidentical
AC outlets quantityKnown for oneUnknown — not stated by the source6 AC outlet(s)
AC outlet typesKnown for oneUnknown — not stated by the sourceNEMA 5–20R
Serial ports quantityKnown for oneUnknown — not stated by the source0
Ethernet LAN (RJ-45) portsKnown for oneUnknown — not stated by the source0
Packaging dataidentical
Package weightKnown for oneUnknown — not stated by the source1.36 kg
Package widthKnown for oneUnknown — not stated by the source229 mm
Package depthKnown for oneUnknown — not stated by the source279 mm
Package heightKnown for oneUnknown — not stated by the source203 mm

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More power distribution units (pdus) comparisons

All power distribution units (pdus) comparisons