Product comparison · 2 network equipment chassis

Allied Telesis AT-CV1000 network equipment chassis vs Allied Telesis AT-MMCR18-00 network equipment chassis 2U Grey

Add a product
  • 7specifications compared
  • 6differ
  • 1identical
  • 15known for one product only

Key differences

Dimensions (WxDxH): 104.8 x 177.7 x 25.4 mm on the Allied Telesis AT-CV1000 network equipment chassis, 440 x 255 x 87 mm on the Allied Telesis AT-MMCR18-00 network equipment chassis 2U Grey. Safety: UL60950-1 (cULUS), EN60950-1 (TUV) on the Allied Telesis AT-CV1000 network equipment chassis, UL, CSA, TUV, IEC 825-1, CE compliant on the Allied Telesis AT-MMCR18-00 network equipment chassis 2U Grey. Operating relative humidity (H-H): 5 - 90% on the Allied Telesis AT-CV1000 network equipment chassis, 5 - 80% on the Allied Telesis AT-MMCR18-00 network equipment chassis 2U Grey. Operating temperature (T-T): 0 - 40 °C on the Allied Telesis AT-CV1000 network equipment chassis, 0 - 50 °C on the Allied Telesis AT-MMCR18-00 network equipment chassis 2U Grey. Storage temperature (T-T): -25 - 70 °C on the Allied Telesis AT-CV1000 network equipment chassis, -20 - 70 °C on the Allied Telesis AT-MMCR18-00 network equipment chassis 2U Grey.

  • Dimensions (WxDxH)
    • AT-CV1000 network equipment chassis:104.8 x 177.7 x 25.4 mm
    • AT-MMCR18-00 network equipment chassis 2U Grey:440 x 255 x 87 mm
  • Operating relative humidity (H-H)
    • AT-CV1000 network equipment chassis:5 - 90%
    • AT-MMCR18-00 network equipment chassis 2U Grey:5 - 80%
  • Operating temperature (T-T)
    • AT-CV1000 network equipment chassis:0 - 40 °C
    • AT-MMCR18-00 network equipment chassis 2U Grey:0 - 50 °C
  • Storage temperature (T-T)
    • AT-CV1000 network equipment chassis:-25 - 70 °C
    • AT-MMCR18-00 network equipment chassis 2U Grey:-20 - 70 °C
  • Weight
    • AT-CV1000 network equipment chassis:470 g
    • AT-MMCR18-00 network equipment chassis 2U Grey:4.3 kg

Side by side

Differences highlightedShow differences only (on)
Comparison of AT-CV1000, AT-MMCR18-00
22 specifications
Technical details1 differ
Rack capacityKnown for oneUnknown — not stated by the source2U
Dimensions (WxDxH)Differs104.8 x 177.7 x 25.4 mm440 x 255 x 87 mm
LED indicatorsKnown for oneUnknown — not stated by the sourceYes
MaterialKnown for oneUnknown — not stated by the sourceMetal
Number of slotsKnown for oneUnknown — not stated by the source18
Operating temperature (T-T)Known for oneUnknown — not stated by the source32 - 122 °F
Product colourKnown for oneUnknown — not stated by the sourceGrey
Certificates1 differ
CertificationKnown for oneUnknown — not stated by the sourceFCC Class A, IC Class A
SafetyDiffersUL60950-1 (cULUS), EN60950-1 (TUV)UL, CSA, TUV, IEC 825-1, CE compliant
Electromagnetic emissionsKnown for oneFCC class A, EN55022 class A, VCCI class A, C-Tick, CE, EN55024Unknown — not stated by the source
Operational conditions3 differ
Operating relative humidity (H-H)Differs5 - 90%5 - 80%
Operating temperature (T-T)Differs0 - 40 °C0 - 50 °C
Storage temperature (T-T)Differs-25 - 70 °C-20 - 70 °C
Operating altitudeKnown for one0 - 3000 mUnknown — not stated by the source
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Weight & dimensions1 differ
DepthKnown for oneUnknown — not stated by the source255 mm
HeightKnown for oneUnknown — not stated by the source87 mm
WeightDiffers470 g4.3 kg
WidthKnown for oneUnknown — not stated by the source440 mm
Poweridentical
Power requirementsKnown for one100 - 240VAC, 50/60HzUnknown — not stated by the source
DC-in requirementsKnown for one12V, 1.06AUnknown — not stated by the source

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.

More network equipment chassis comparisons

All network equipment chassis comparisons