Product comparison · 2 network equipment chassis

Allied Telesis 18-slot 2U, rack-mountable chassis for Converteon™ blades vs D-Link DES-6510 network equipment chassis

Add a product
  • 4specifications compared
  • 4differ
  • 0identical
  • 16known for one product only

Key differences

LED indicators: Yes on the Allied Telesis 18-slot 2U, rack-mountable chassis for Converteon™ blades, Link, Power, Yes on the D-Link DES-6510 network equipment chassis. Operating temperature (T-T): 0 - 40 °C on the Allied Telesis 18-slot 2U, rack-mountable chassis for Converteon™ blades, 0 - 50 °C on the D-Link DES-6510 network equipment chassis. Storage temperature (T-T): -25 - 70 °C on the Allied Telesis 18-slot 2U, rack-mountable chassis for Converteon™ blades, -25 - 55 °C on the D-Link DES-6510 network equipment chassis. Power requirements: 90-240VAC@47/63Hz on the Allied Telesis 18-slot 2U, rack-mountable chassis for Converteon™ blades, 90-264 V on the D-Link DES-6510 network equipment chassis.

  • LED indicators
    • 18-slot 2U, rack-mountable chassis for Converteon™ blades:Yes
    • DES-6510 network equipment chassis:Link, Power, Yes
  • Operating temperature (T-T)
    • 18-slot 2U, rack-mountable chassis for Converteon™ blades:0 - 40 °C
    • DES-6510 network equipment chassis:0 - 50 °C
  • Storage temperature (T-T)
    • 18-slot 2U, rack-mountable chassis for Converteon™ blades:-25 - 70 °C
    • DES-6510 network equipment chassis:-25 - 55 °C
  • Power requirements
    • 18-slot 2U, rack-mountable chassis for Converteon™ blades:90-240VAC@47/63Hz
    • DES-6510 network equipment chassis:90-264 V

Side by side

Differences highlightedShow differences only (off)
Comparison of 18-slot 2U, rack-mountable chassis for Converteon™ blades, DES-6510
20 specifications
Technical details1 differ
Rack mountingKnown for oneYesUnknown — not stated by the source
Dimensions (WxDxH)Known for one342.5 x 440.5 x 86.8 mmUnknown — not stated by the source
LED indicatorsDiffersYesLink, Power, Yes
Size (imperial)Known for one48.3 cm (19")Unknown — not stated by the source
Data transfer rateKnown for oneUnknown — not stated by the source0.1 Gbit/s
Host interfaceKnown for oneUnknown — not stated by the sourceRJ-21, RJ-45
Ports quantityKnown for oneUnknown — not stated by the source26
Certificatesidentical
SafetyKnown for oneUL60950-1 (cULUS), EN60950-1 (TUV)Unknown — not stated by the source
Electromagnetic emissionsKnown for oneFCC class A, EN55022 class A, VCCI class A, C-Tick, CE, EN55024Unknown — not stated by the source
Operational conditions2 differ
Operating altitudeKnown for one0 - 3048 mUnknown — not stated by the source
Operating relative humidity (H-H)Known for one5 - 90%Unknown — not stated by the source
Operating temperature (T-T)Differs0 - 40 °C0 - 50 °C
Storage relative humidity (H-H)Known for one5 - 95%Unknown — not stated by the source
Storage temperature (T-T)Differs-25 - 70 °C-25 - 55 °C
Power1 differ
Power requirementsDiffers90-240VAC@47/63Hz90-264 V
Weight & dimensionsidentical
WeightKnown for one7.5 kgUnknown — not stated by the source
DepthKnown for oneUnknown — not stated by the source281 mm
HeightKnown for oneUnknown — not stated by the source27.5 mm
WidthKnown for oneUnknown — not stated by the source330 mm
Networkidentical
Cabling technologyKnown for oneUnknown — not stated by the source10/100M BASE-T

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.