Product comparison · 2 digital & analog i/o modules

Brainboxes ED-504 digital/analogue I/O module vs Brainboxes Ethernet to 8 Channel Thermocouple Input

Add a product
  • 25specifications compared
  • 21differ
  • 4identical
  • 20known for one product only

Key differences

The Brainboxes Ethernet to 8 Channel Thermocouple Input has 4 channels more channels quantity than the Brainboxes ED-504 digital/analogue I/O module (8 channels vs 4 channels). The Brainboxes ED-504 digital/analogue I/O module has 1 more Ethernet LAN (RJ-45) ports than the Brainboxes Ethernet to 8 Channel Thermocouple Input (2 vs 1). The Brainboxes ED-504 digital/analogue I/O module has 10 V more maximum output voltage than the Brainboxes Ethernet to 8 Channel Thermocouple Input (40 V vs 30 V). Module type: Digital on the Brainboxes ED-504 digital/analogue I/O module, Analog on the Brainboxes Ethernet to 8 Channel Thermocouple Input. Signal direction: Input/output on the Brainboxes ED-504 digital/analogue I/O module, Input on the Brainboxes Ethernet to 8 Channel Thermocouple Input.

  • Module type
    • ED-504 digital/analogue I/O module:Digital
    • Ethernet to 8 Channel Thermocouple Input:Analog
  • Signal direction
    • ED-504 digital/analogue I/O module:Input/output
    • Ethernet to 8 Channel Thermocouple Input:Input
  • Channels quantity
    • ED-504 digital/analogue I/O module:4 channels
    • Ethernet to 8 Channel Thermocouple Input:8 channels
  • Serial interface type
    • ED-504 digital/analogue I/O module:RJ-45, RS-232/422/485
    • Ethernet to 8 Channel Thermocouple Input:RS-485
  • Ethernet LAN (RJ-45) ports
    • ED-504 digital/analogue I/O module:2
    • Ethernet to 8 Channel Thermocouple Input:1
  • Maximum output voltage
    • ED-504 digital/analogue I/O module:40 V
    • Ethernet to 8 Channel Thermocouple Input:30 V
  • Product colour
    • ED-504 digital/analogue I/O module:Yellow
    • Ethernet to 8 Channel Thermocouple Input:Multicolour
  • Power consumption
    • ED-504 digital/analogue I/O module:60 mA
    • Ethernet to 8 Channel Thermocouple Input:100 mA

Side by side

Differences highlightedShow differences only (on)
Comparison of ED-504, ED-593
45 specifications
Features10 differ
Module typeDiffersDigitalAnalog
Signal directionDiffersInput/outputInput
Channels quantityDiffers4 channels8 channels
Digital input channels quantityKnown for one4 channelsUnknown — not stated by the source
Digital output channels quantityKnown for one4 channelsUnknown — not stated by the source
Serial interface typeDiffersRJ-45, RS-232/422/485RS-485
Ethernet LAN (RJ-45) portsDiffers21
Supported network protocolsDiffersICMP, IP, TCP, DHCP, Telnet, HTTPICMP, IP, TCP, DHCP, HTTP
Maximum output voltageDiffers40 V30 V
Maximum output current per channelKnown for one0.85 AUnknown — not stated by the source
Maximum combined loadKnown for one4 AUnknown — not stated by the source
Electrostatic Discharge (ESD) protectionKnown for one16 kVUnknown — not stated by the source
Overheat shutdown (typical)Known for one150 °CUnknown — not stated by the source
Overheat shutdown (min)Known for one175 °CUnknown — not stated by the source
Short circuit protectionKnown for oneYesUnknown — not stated by the source
Short circuit protection up toKnown for one36 VUnknown — not stated by the source
Windows operating systems supportedDiffersWindows 10, Windows 2000, Windows 7, Windows 7 x64, Windows 8, Windows 8 x64, Windows Vista, Windows Vista x64, Windows XP, Windows XP x64Windows 10, Windows 7, Windows 7 x64, Windows 8, Windows 8 x64, Windows Vista, Windows Vista x64, Windows XP, Windows XP x64
Linux operating systems supportedKnown for oneYesUnknown — not stated by the source
Mac operating systems supportedKnown for oneYesUnknown — not stated by the source
Server operating systems supportedDiffersWindows Server 2008, Windows Server 2008 R2, Windows Server 2008 R2 x64, Windows Server 2008 x64, Windows Server 2012, Windows Server 2012 x64Windows Server 2008, Windows Server 2008 x64
Mobile operating systems supportedKnown for oneAndroid, iOSUnknown — not stated by the source
Product colourDiffersYellowMulticolour
CertificationKnown for oneC-Tick, AEO (C-TPAT), WEEE, RoHSUnknown — not stated by the source
I/O protocolsKnown for oneUnknown — not stated by the sourceDCON ASCII (over TCP or Virtual COM port)
DIN rail mountingKnown for oneUnknown — not stated by the sourceYes
Power3 differ
Power consumptionDiffers60 mA100 mA
Power consumption noteKnown for one1.6 - 2.9WUnknown — not stated by the source
DC input voltageDiffers+5V - +30V5 - 30 V
Maximum input voltageDiffers35 V30 V
Operational conditions1 differ
Operating temperature (T-T)Differs-30 - 80 °C-40 - 80 °C
Relative humidityKnown for one5 - 95%Unknown — not stated by the source
Weight & dimensions7 differ
WidthDiffers22.6 mm135 mm
DepthDiffers114.5 mm160 mm
HeightDiffers99 mm49 mm
WeightDiffers121 g192 g
Package widthDiffers50 mm135 mm
Package heightDiffers140 mm49 mm
Package weightDiffers217 g192 g
Technical detailsidentical
Compliance certificatesKnown for oneUnknown — not stated by the sourceCE, Federal Communications Commission (FCC), KCC, UKCA, UL
Logistics dataidentical
Country of originKnown for oneUnknown — not stated by the sourceUnited Kingdom
Export Control Classification Number (ECCN)Known for oneUnknown — not stated by the source5A991.b

A dash means the value is not stated by the source. Unknown values are never counted for or against a product, and there is no overall score.